32
B U I L T - I N R E S E T B U T T O N
A U D I O A L A R M
When the gate operator’s audio alarm (See below) has been tripped, the reset button must be
pushed for the operator to function again.
The reset button will shut off an activated audio alarm and reset the operator to function again.
If the audio alarm goes off, always check the gate area for:
• Obstructions in the gate path.
• Damage to the gate and/or gate operator.
The operator arm or gate is incorrectly installed.
The gate is TOO heavy.
An externally wired safety sensor has been
triggered twice. (Photo beam blocked)
Gate hinges are too tight, broken or the gate is not moving freely.
The gate is moving and a car pushes the gate.
A foreign object is on the gate
frame while the gate is moving.
Press the Built-In Reset Button to Shut Off Alarm and Reset Operator (See above)
Pressing the reset button will stop a moving gate during a normal
open/close cycle, like a stop button. The operator does
NOT
need to
be reset after doing this.
Party Mode (Timer Defeat - Hold Open)
When the “Timer to Close” feature is activated for normal daily
operation and you wish to leave the gate(s) in the open position for any
extended period of time you can activate the “Party Mode” by pushing
the “Reset Button” located on the outside of the electrical box. To exit
this mode, simply give the gate(s) a command to run by using the
remote control. This will close the gate(s) and return the operator to
normal operation.
The alarm could be tripped when one of the following happens
Twice Consecutively,
then the alarm will sound for
5 minutes or until the reset button is pressed!
UL Alarm