MOUNT POWER SUPPLY (CONTINUED)
• Connect and firmly secure 2 conductor wires to the
terminals marked
COM
and
24Vac
on the power supply
provided. Refer to ‘Wire Table’ for recommended wire
size and distance from the power supply and the gate
operator control box (Figure 2).
• Pull wire through one of the water tight connector nuts
located on the bottom of the control box. Tighten nut
firmly. Pull gently on the wire to confirm it is secure
(Figure 3).
• Connect and firmly secure the wires from the power
supply to the control board terminals marked
24Vac
(Figure 3).
1
2V
C
O
M
2
4V
Power Supply
Wiring to
Control Box
24
V
AC
Figure 3
Figure 2
Distance from indoor AC
Outlet to Control Box
Wire Gauge Needed
100 ft. (30.5 m) or less
16 gauge (917GA)
100 - 150 ft. (30.5 - 45.7 m)
14 gauge*
150 - 250 ft. (45.7 - 76.2 m)
12 gauge*
250 ft. (76.2 m) and above
Not Recommended
* UL Listed, Stranded, Direct Burial, UV Resistant Wire
Installed per the National Electric Code, NEC.
11
Installation
Operator
Cable
Watertight
Connector Nut
Control Box