Operation and Maintenance
38
* Class 2 circuit 15 v maximum output
2. Close edge
3. Open edge/photo eye
4. Open photo eye
5. Close photo eye
6. Control inputs
7. Loop inputs
10. Accessory power
12. Automatic gate lock
13. Fault alarm
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE installing or servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
EDGE
EDGE
916GA SAFETY SENSORS
916GA SAFETY SENSORS
OR
OPEN (EXI T LOOP)
SINGLE BUTTON (SBC)
RESET
STOP
SHADOW LOOP
INTERRUPT LOOP
916GA SAFETY SENSORS
6
7
14
2
3
4
5
1
15
8
18
23
CLOSE
EDGE
R93
D42
K2
D1Ø
OPEN EDGE/
PHOTO
OPEN
PHOTO
CLOSE
PHOTO
Z22
P1
F2
MO
V1
D1
Q12
U4
CONTROL
INPUTS
FORCE
TIMER TO
CLOSE
OFF
MAX
OPEN
SINGLE BUTTON
RESET
STOP
SHADOW
INTERRUPT
CHGR
OVLD
CTRL PWR
CTRL
LOOP
INPUTS
D129
Z4
U3
D2
D44
C11
C13
C12
D16
F9
R1Ø1
R1ØØ
K1
Q22
F3
K3
K4
R196
F1
Z12
GATE 2
ACCESSORY
POWER
ALARM
GATE 1
MAGR
SOL
GR
WH
YL
BL
RD
BR
GR
WH
YL
BL
RD
BR
F7
12 V
CTRL
OVLD
TIMER
RUNNING
GATE 2
SET
OPEN
LIMIT
SET
CLOSE
LIMIT
LEARN
LIMITS
DIAGNOSTIC
GATE 1
LEARN
XMITTER
LOCK /
ON
OFF
PWR
C69
OFF
MAX
J2
Ø
PWR
SINGLE BUTTON
AC PWR
/SOLAR
D8
D4
R9
R329
R27
MO
V2
R4
C2
BIPART DELAY
LOCK
GND
Z1
R1
R2
K5
F12
Q9
R9Ø
F8
Q6
Q1
J19
ACCESSORY
0VLD
R182
C1Ø1
C75
C73
C72
C71
C7Ø
C66
C65
C68
C33
F11
R186
R42Ø
R423
J24 J23 3
Ø
A 32V
3
Ø
A 32V
J21
2Ø
30
C64
R22
U2
J18
K6
JU1
JU2
DB1
D36
R184
16
19
17
18
13
(optional)
Fault Alarm
Automatic Gate Lock
WHT
GRN
BRN
YEL
BLU
RED
WHT
GRN
BRN
YEL
BLU
RED
11
10
9
20
21
22
CTRL PWR
24
OR OPTIONAL SOLAR PANEL
12
RED
RED
BLK
BLK
Gate 1 (Master)
Gate 2 (Second)
RED
BLK
OPTIONAL GROUND ROD
NOTE:
For all installations use
the 14.5V output on transformer.
NOTE:
Batteries MUST
be connected to operate.
*
*
*
*
*
*
*
*
*
Wiring Diagram
To protect against fire and electrocution:
• DISCONNECT power and battery BEFORE installing or
servicing operator.
For continued protection against fire:
• Replace ONLY with fuse of same type and rating.
17. Learn Xmitter
18. Primary Gate Jog
19. Learn Limits
20. Secondary Gate Jog
21. Force
22. Timer To Close
23. Receiver Module
24. Fuses (20 Amp)
9. Gate 2
10. Accessory Power*
11. Gate 1
12. Lock (Solenoid/Maglock) Output*
13. Alarm Output*
14. Battery 1 Connector
15. Battery 2 Connector
16. Lock/BiPart Delay
1. Antenna Input
2. Close Edge*
3. Open Edge/Photo*
4. Open Photo*
5. Close Photo*
6. Control Inputs*
7. Loop Inputs*
8. AC PWR/SOLAR
*Class 2 circuit 15 V maximum output
Summary of Contents for GA400D