P R O G R A M M I N G

TIMER TO CLOSE (TTC)

Timer to Close feature enables the operator to close the door after 

a preset time, adjustable from 5 to 60 seconds. LMEP must be 

connected and unobstructed in order to activate this feature. See 

installation section for proper LMEP installation.

PROGRAMMING TTC

1.  Begin with door in fully closed position
2.  Press and release the LEARN button (DIAGNOSTIC LED will 

light.)

3.   Press and release the TTC button.
4.   Every press and release of the STOP button will add 5 seconds 

to the Timer to Close. Example: 30 second TTC = 6 presses of 

the STOP button.

5.   Press and release the TTC button to exit programming mode.
6.   The DIAGNOSTIC LED will flash once per 5 seconds of timer 

setting.

The TTC will become active after completion of the next open 

cycle.
NOTE: LED does not indicate that timer is running.

CLEARING TTC

1.   Press and release the LEARN button (DIAGNOSTIC LED will 

light.)

2.   Press and hold the TTC button for at least 6 seconds.
3.  DIAGNOSTIC LED will flash rapidly when button is released.

TIMER DEFEAT

The TTC can be temporarily disabled by pressing the STOP button 

on the logic board or STOP button on the 3-button control 

station.
TTC becomes active after next open cycle

DETERMINE AND SET WIRING TYPE MODE

Read the descriptions of the wiring types to determine which 

setting will be correct for each application.

TYPE

C2   Momentary contact to open and stop with constant pressure 

to close, open override plus wiring for sensing device to 

reverse. Timer to Close feature not available.

B2   Momentary contact to open, close and stop, open override 

plus wiring for sensing device to reverse. Timer to Close 

(TTC) feature available. (LMEP is required for this wiring

type mode).

The operator factory defaults to C2 mode when installed without a 

LiftMaster Monitored Entrapment Protection (LMEP) device and 

B2 mode when an LMEP is installed.
•   If C2 mode is desired in conjunction with an installed LMEP 

press and hold LEARN and CLOSE for 3 seconds until 

DIAGNOSTIC LED goes off. 

•   To return to standard operation press and hold LEARN and 

Stop for 3 seconds until DIAGNOSTIC LED goes off.

PROGRAMMING REMOTE CONTROLS

Built in 315 MHz radio receiver permits as many as 20 

Security

®

 remote controls or dip switch remote controls in any 

combination.

SINGLE BUTTON REMOTE CONTROLS

1.    Press and release the LEARN button (DIAGNOSTIC LED

will light.)

2.    Press and hold the button on the remote 

control until the Diagnostic LED flashes 

rapidly, then release to complete 

programming (LED will go out).

3.    Repeat steps 1 and 2 for additional 

remotes.

3-BUTTON REMOTE CONTROLS

1.    Press and release the LEARN button (DIAGNOSTIC LED will 

light.)

2.    Press and release the 

desired function for the 

remote button (OPEN, 

CLOSE or STOP.)

3.    Press and hold the 

desired button of the remote control until DIAGNOSTIC LED 

flashes rapidly, then release.

4.    Repeat for programming other buttons that are desired.

ERASING REMOTE CONTROLS

Press and hold the LEARN button (over 5 seconds) until the 

DIAGNOSTIC LED flashes rapidly. All learned remote controls will 

be erased.

DIAGNOSTIC

D14

LEARN

ST

DIAGNOSTIC

D14

C18

LEARN STOP

CLOSE OPEN

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this 

receiver and/or transmitter are prohibited, except for changing the code setting or replacing the 

battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device 

must accept any interference received, including interference that may cause undesired operation.

MODE 

OPEN 

CLOSE 

STOP 

REVERSE FROM   TTC

 

 

    CLOSING RESET

B2  X X X 

X

B2      

 

with 

 

X WHEN

TTC      

  OPEN

C2 

X   X 

X

RADIO OPERATION

To prevent possible SEVERE INJURY or DEATH, install 

reversing sensors when:
• The radio is used. 
• The 3-button control station is out of sight of the door.
• Or ANY other control (automatic or manual) is used. 
Reversing devices are recommended for ALL installations.