To prevent possible SERIOUS INJURY or DEATH from electrocution 
or fire:

•   Disconnect power to opener BEFORE proceeding.

•   NEVER use an extension cord, 2-wire adapter, or change plug in 

any way to make it fit outlet. Be sure the opener is grounded.

WARNING

CAUTION

WARNING

WARNING

WARNING

Models 580LM & 580LMC

Residential Jackshaft Opener Alternate 

Power System Accessory 

Disconnect all power to the opener if already installed. 
Disconnect the Standby Power Unit

®

 from the opener if it is 

installed.

Determine mounting location for the interface within 
3' (.9 m) of opener. Mount and secure with screws and 
anchors.

Plug interface into opener.

Position transformer within 1' (.3 m) of outlet, secure with 
screws and anchors. 

NOTE: 

If transformer is being secured to ceiling, the 

transformer must be secured to a ceiling joist

.

Separate low voltage wires. One end of the wire is prepared 
for convenience. Cut wire to appropriate length and strip 
7/16" (11 mm) of insulation from the end of the wire.

Use one of the stripped wires to connect 

COM

 screw 

terminals on the interface and transformer. Use the other 
stripped wire to connect 

24V

 screw terminals. (Polarity is 

not important.)

Before permanently mounting, reduce slack in cord. Secure 
with insulated staples.

Use cable tie to bind power cord from opener. Be sure to 
keep power cord away from rail and out of the reach of 
children.

Plug transformer into the outlet. To reduce the risk of electric 
shock, your garage door opener has a grounding type plug 
with a third grounding pin. This plug will only fit into a 
grounding type outlet. If the plug doesn’t fit into the outlet 
you have, contact a qualified electrician to install the proper 
outlet.

NOTE: 

Opener may operate at a slower speed while using 

this device.

Connect to Standby Power Unit

®

 (SPU) 

(Not Provided) (Figure 2)

Connect the SPU connector from the SPU to the interface.

NOTE:

 If connecting to a standby power unit, the interface and 

SPU must be within 3' (.9 m) of each other. 

Transformer (1)

Interface (1)

Anchor (8)

Screws (8)

Cable Tie (1)

Low Voltage Wire 35'

Insulated Staples (30)

Carton Inventory

1

2

3

4

5

6

7

8

9

Installation (Figure 1)

Figure 1

Figure 2

NOTE:

 For use only with Residential Jackshaft Openers.

NOTE: 

If the Smart Control Panel is showing the message 

“Battery Back-up enabled” or the LCD Backlight is not on under 
power from the Alternate Power System contact service at
1-800-528-9131.

Optional Low Voltage Wire 50' 

(Not Shown) 41A6669