C O N T R O L   B O A R D   L A Y O U T

COMPONENT LOCATIONS

Accessory power is 24 Vdc regulated rated at 500 ma. [1/2 amp].

J5 #4 

for use with hard wired line of sight devices to open gate and reset unit.

 D11:

 Heart beat. Shows that processor and program routine are running properly.

 D12:

 Battery status. See diagnostic procedures on page 17.

 D14:

 AC power indicator. Shows that ac power is present.

 F3:

 15 amp ATO type fuse for 24 Vac input power. (UL listed fuse only.)

 F4:

 15 amp ATO type fuse for 24 Vdc battery input power. (UL listed fuse only.)

 JP2:

 Input for photo beam used as secondary entrapment protection.

24VAC XFMR

ACC+

HBEAT

BAT LO AC POWER

PWR

C NC NO

Aux Relay

R2

R11

D1

Q1

DC

1

1

K1

D11

D12

R13

D14

U19

J4

F3

F4

F1

F2

1A   DC

IRD1

R63

J1

ACC–

BAT–

BAT–

MOV

BAT+

MOTOR

MOTOR

AUX LIMITS

1

J2

J3

J5

M/S

JP2

S3

1

Q2

T2

1

2

3

4

5

6

7

8

9

1Ø 11 12

T1

OPEN 1

D15

C7

X2

C19

D7

OLS

R1

U1

C2

C3

C4

C1

U4

R12

S1

D6

OPEN

D5

BRAKE

D4

CLOSE

D3

CLS

D2

IRD

OPEN 2

D16

R3

Ø

OPEN 3

D17

AUX 4

D18

SAFETY 5

D19

CLOSE 6

D22

BACK 7

D23

SHADOW 8

D24

OPEN

CLOSE

MANUAL

R1

Ø

R9

R38

R15

R37

C8

C2Ø

C12
U12

U1Ø

+

R8

R7

R6

R5

U2

U3

CPU

U5

U6

U7

X1

R4

R3

D8

T4
T3

T6
T5

T8
T7

C15

C2

D27

Q6

Q5

F5

C22

C18

U18

1 2 3 4 5 6 7 8 

S2

1 2 3 4 5 6 7 8 

D1Ø

R14

R18

R21

R24

R36

R42

R47

R53

R35

R41

R46

R5Ø

R61

C16

R17

R16

D29

Q4

D28

D26

C6

D25

B2

+

U8

U9

U16

U11

U13

U14

U15

D9

R23

R22

R26

R25

R19

B1

R

C5

+

+

R34

R33

R

R39

R45

R44

R58

DX3

R49

R48

R43

R51

WARNING FOR
CONTINUOUS
PROTECTION
AGAINST FIRE
REPLACE ONLY
WITH THE SAME
TYPE AND RATING
OF FUSE

R43

R

R59

D21

D2

Ø

R62

DX1

TR

DX4

R57

R56

C13

DX2

R55

Open Gate Inputs - Reader, Push Button

Aux Open / Reset (Pulse Open/Close)

Close Gate Input - Close Loop

Back Away - Free Exit Loop

Commons - 0 Vdc

Shadow Loop

Safety Loop Input

K1 Relay Terminals 

(Optional)

Relay (Optional)

Relay Indicator

Obstruction Sense 

(IRD and MRT)

Close Limit Sensor

Close Drivers On

Motor Brake On

Open Drivers On

Open Limit Sensor

24 Vdc (Regulated)

YEL

YEL

RED

ORG

BLU

BLK

Summary of Contents for LiftMaster MEGA SLIDE-X

Page 1: ...AL DUTY SLIDE GATE OPERATOR OWNER S MANUAL THIS UNIT IS A CLASS 1 2 3 OR 4 SLIDE GATE OPERATOR FOR USE IN SLIDE GATE APPLICATIONS The Chamberlain Group Inc 845 Larch Avenue Elmhurst Illinois 60126 119...

Page 2: ...cess Control Device 18 Dual Direction as Entry and Free Exit 18 CONTROL BOARD LAYOUT Component Locations 19 REPAIR PARTS 20 ACCESSORIES 21 SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION 22 REP...

Page 3: ...e motor allowing the gate to be manually opened Normal Operation Position Manual Release Position I N T R O D U C T I O N CARTON INVENTORY Before beginning your installation check that all components...

Page 4: ...thods must be designed arranged or configured to protect against entrapments in both the open and close directions of gate travel For Example For a slide gate system that is installed on a single fami...

Page 5: ...tivation must be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor o...

Page 6: ...op photo beam should be installed along the gate s path that is covered when open Photo beams are to be installed according to their manufacturer s instructions and are to be placed in areas that pose...

Page 7: ...both inside and outside of a vehicular horizontal slide gate Non contact sensors such as photo eyes must protect during both open and close gate cycles Injuries occur when people put their hands and a...

Page 8: ...t Direct drive gear reducer eliminates many parts that might otherwise fail State of the art MOSFET motor drive technology NO contactors or relays Dynamic motor braking to preserve gate stopping point...

Page 9: ...UITS Use the open area in base of the unit to position your conduits 12 0 wide by 10 75 deep Use 1 2 or 3 4 inch UL listed conduits Please observe any requirements in your local electrical code NOTE D...

Page 10: ...e cleared and secured at that time the unit may be returned to service Disconnecting power at the fuse box BEFORE proceeding Operator MUST be properly grounded and connected in accordance with local e...

Page 11: ...or 5 minutes after 2nd sequential obstruction then turns itself off however operator will require a reset signal to J5 4 to re activate gate In addition cycling the ac power will also reset unit Termi...

Page 12: ...rol detectors receivers keypads timers etc wires to it must also be run to the same terminals of the second Along with these control wires both operators MUST share a common ground connection from cha...

Page 13: ...of the slide gate to reduce the possibility of injury to persons that may attempt to walk through gate opening Along with the beams it is strongly recommended that pressure sensing edges be installed...

Page 14: ...ed by turning the IRD1 to the right CW more sensitive or left CCW less sensitive in small increments ADJUSTMENT While running the gate open and closed verify that the gate travels as expected Verify t...

Page 15: ...a screwdriver Re connect power to opener Figure 2 2 Press and release the learn button on the receiver The learn indicator light will glow steadily for 30 seconds 3 Within 30 seconds press and hold t...

Page 16: ...trol Board Layout page Replace batteries with LiftMaster P N MBAT batteries Replace in pairs BATTERY DISPOSAL Replaced batteries must be treated as a hazardous waste and disposed of in accordance with...

Page 17: ...VERTENCIA ADVERTENCIA Gate will not operate Is the HBEAT flashing Check the battery connections Check fuse F4 Replace if blown No Is the battery lo LED on Is the HBEAT flashing now Yes Is S2 8 open on...

Page 18: ...n inputs DUAL DIRECTION AS ENTRY AND FREE EXIT Dual direction is a combination of both of the above configurations to provide the ability for traffic to enter or exit in the same lane Figure 3 RECOMME...

Page 19: ...C2 C3 C4 C1 U4 R12 S1 D6 OPEN D5 BRAKE D4 CLOSE D3 CLS D2 IRD OPEN 2 D16 R3 OPEN 3 D17 AUX 4 D18 SAFETY 5 D19 CLOSE 6 D22 BACK 7 D23 SHADOW 8 D24 OPEN CLOSE MANUAL R1 R9 R38 R15 R37 C8 C2 C12 U12 U1 R...

Page 20: ...043 Limit Nuts 11 MS013 Detent Plate 12 MS014 Siren 100 db 13 MS015 Transformer 120 230 Vac 24 Vac 14 MS016 120 Vac Duplex Outlet 120 Vac Only 15 MS018 Idler Pulley Bolt Washer and Nut 16 MS019 120 Va...

Page 21: ...1 Heater Option 150 watt with thermostat MBAT Replacement Battery 1 12V 7Amp Battery 2 required per operator MA200 SAMSKIT K1 Relay Output Option Accessory relay for external signaling common N C N O...

Page 22: ...23 Miller Edge Normally open contact MG 020 Miller Edge Normally open contact MG020 Miller Edge Normally open contact MGR20 Miller Edge Normally open contact MGS20 Miller Edge Normally open contact HO...

Page 23: ...A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE 2 YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE EXCEPT THE IMPLIED WARRANTIES WITH RESPECT TO THE COVER AND CHASSIS WHICH ARE LIMITED IN DURATION TO...

Page 24: ...and operator required _____ This class operator is approved for the application of the operator 1 2 3 or 4 required _____ A sphere with a 2 1 4 diameter cannot be pushed through the gate or fixed pan...

Reviews: