background image

STANDBY POWER UNIT

Model 475LM Owner’s Manual

INSTALLATION
Mounting the standby power unit (SPU) can be done using one 

of two methods. The SPU can be mounted directly on top of the 

motor unit or it can be secured on a structural support just 

above it.

1. Mounting the SPU Directly to the Motor Unit.
•   Position the SPU on top of the motor unit. Make sure the 

motor unit power cord is drawn out from beneath the SPU. 

The SPU should sit firmly on top of the motor unit. Adjust 

angle iron placement so that it is out of the way of the SPU’s 

installation (Figure 1).

•   Align the two screw slots on the SPU to the back chassis 

holes.

•   Secure the SPU to each side of the chassis flanges with 3/4" 

screws provided.

2.  Mounting the SPU Directly to a Structural Support.
•   After the motor unit has been installed, the SPU can be 

mounted to either the ceiling or a wall within 3' (.9 m) of the 

motor unit.

•   Position the SPU as desired to a structural support (ceiling 

joist or wall stud) (Figure 2).

•   Attach the SPU to the support using the mounting holes on 

either side of the SPU.

•   Secure the SPU using the 1-1/2" lag screws (provided).

3. Connect the SPU to the Motor Unit.
•   Disconnect the motor unit from the electrical outlet.
•   Connect the SPU cord into the connector on the 

end panel on the motor unit. Connect the motor 

unit to the electrical outlet. The SPU will activate 

and all LEDs will turn on for 3 seconds.

•   The green LED will begin flashing, indicating the 

SPU is charging from the motor unit.

IMPORTANT NOTE: Installation of SPU when 

permanent electrical power is not available (such as 

new construction and the electricity is not installed) 

may damage the batteries. Unplug SPU after testing 

to prevent damage.

 

 

Figure 1

Figure 2

To prevent possible SERIOUS INJURY or DEATH from 

electrocution, disconnect ALL electric and battery power 

BEFORE performing ANY service or maintenance.

ALWAYS wear protective gloves and eye protection 

when changing the battery or working around the battery 

compartment.

Power Cord

Power Cord

SPU Cord

SPU 

Connector

SPU Cord

475LM Standby 

Power Unit

475LM Standby 

Power Unit

Bring Power 

Cord out left 

side slot

Bring SPU Cord out right 

side slot away from Antenna

Side Screw 

Slots for 

Chassis Mount

Standby Power 

Unit (SPU)

Holes for 

Ceiling 

Mount

Lag 

Screw 

1-1/2"

Structural 

Supports

Lag Screws 

1-1/2"

3/4" Screw

3/4" Screw

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334

Reviews: