background image

13

I N S TA L L I N G   T H E   R E C E I V E R

To prevent possible SERIOUS INJURY or DEATH from a moving
gate or garage door:
• ALWAYS keep remote controls out of reach of children.

NEVER permit children to operate, or play with remote control
transmitters.

• Activate gate or door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door travel.

• ALWAYS keep gate or garage door in sight until completely closed

NEVER permit anyone to cross path of moving gate or door.

WARNING

CAUTION

WARNING

WARNING

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

HIGH 

SECURITY MODE

Security Mode
Terminals

Jumper

NORMAL 

SECURITY MODE

Security Mode
Terminals

Jumper

FIGURE 2

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.

WIRING THE RECEIVER

Contacts 1 and 2 on the receiver terminal strip are for power. The
power terminals are unpolarized. Connect terminals 1 and 2 to
the accessory power terminals on the S4 terminal strip at the
bottom of the logic board (Figure 1).

Contacts 3 and 4 on the receiver terminal strip are for a common
and a relay. Connect terminals 3 and 4 to terminals 1 and 10 on
the S5 terminal strip at the top of the logic board.

SET SECURITY MODE

The Universal Receiver can be used with up to 15 rolling code
remotes or passwords in HIGH security mode. Alternately, it can
be used with up to 31 of any type remote in NORMAL security
mode, including any combination of rolling code, billion code, or
dip switch remotes.

The jumper must be set at the HIGH position for the receiver to
operate in HIGH security mode. It must be set at NORMAL
position to operate at the NORMAL mode (Figure 2).

When changing from NORMAL to HIGH security mode, any
previous remote codes must be erased. Repeat Steps 2 and 3 in
the Programming Section below to reprogram the receiver for
each remote control in use.

The receiver is factory set at HIGH.

PROGRAMMING THE REMOTE TO THE RECEIVER

STEP 1:

Pry open the front panel of receiver case with a coin or

a screwdriver. Re-connect power to opener (Figure 3).

STEP 2:

Press and release the “learn” button on the receiver.

The learn indicator light will glow steadily for 30 seconds.

STEP 3:

Within 30 seconds, press and hold the button on the

hand-held remote that you wish to operate your gate.

The opener will now operate when the push button on either the
receiver or the remote control is pressed.

Repeat Steps 2 and 3 for each remote control that will be used to
operate the gate.

TO ERASE ALL REMOTE CONTROL CODES

Press and hold the “learn” button on the receiver panel until the
indicator light turns off (about 6 seconds). All remote codes are
now erased. Then follow the steps above to reprogram each
remote control.

24V 12V

HIGH NORM

C
P2
M

Learn Button

Indicator Light

Output Duration
Terminals

Security Mode

Power Supply 
Jumper

OPEN RECEIVER

FIGURE 3

OPENING  RECEIVER

Connect 
Antenna

(Not
Provided)

ACC+

BAT– BAT

BAT–

BAT+

ACC–

J4

Jumper P1 to J4 Accessory Power
Jumper P2 to J4 Accessory Power
Jumper P3 to J5 Terminal 1
Jumper P4 to J5 Terminal 10

1

2

3

4

5

6

7

8

9

10

11

J5

2

3

4

1

+

10

1

FIGURE 1

Summary of Contents for LIFTMASTER PROFESSIONAL MSLDCBB

Page 1: ...unit must only be installed by an experienced technician Disconnect AC power and batteries before servicing IMPORTANT Read and understand Warranty Page first Batteries not included MUST be connected f...

Page 2: ...t Locations 16 MEGA SLIDE UL PARTS LIST Part Numbers and Descriptions 17 Parts Shipped 17 OPERATOR NOTES 18 WARRANTY 19 REPAIR PARTS AND SERVICE 20 TA B L E O F C O N T E N T S IMPORTANT SAFETY INSTRU...

Page 3: ...is class operator is approved for the application of the operator 1 2 3 or 4 required ______ A sphere with a 2 1 4 diameter cannot be pushed through the gate or fixed panel ______ A safety screen mesh...

Page 4: ...erator must be in the line of sight and must be an intended reset Access control devices of any kind that required intended on purpose activation may be used for this reset Devices that will cause an...

Page 5: ...e secondary stop photo beam should be installed along the gate s path that is covered when open Photo beams are to be installed according to their manufacturer s instructions and are to be placed in a...

Page 6: ...ds installed covering all cantilever wheels required All controls located far out of reach of gate fixed panel and operator required This class operator is approved for the application of the operator...

Page 7: ...y to persons use photo electric eyes on both sides of gate and pressure sensing edges at all pinch points and at the front leading edge of the gate Safety loops vehicle detectors should be installed i...

Page 8: ...helf maybe installed after all conduits are cut to proper height and all wiring has been properly routed NOTE Do not attempt to hook up the 120VAC mains if wires are LIVE or HOT Be sure power is off C...

Page 9: ...is input to reset the unit after a 2nd sequential obstruction is sensed and gate is locked with siren running This input normally functions as listed below Acts same as 1 2 3 above with S2 6 off With...

Page 10: ...R any input at J5 with control detectors receivers keypads timers etc wires to it must also be run to the same terminals of the second Along with these control wires both operators MUST share a common...

Page 11: ...delay if activated MODE SELECTIONS SWITCH PACK S2 6 8 SWITCH 6 Sets auxiliary open input terminal 4 at J5 to be pulse open pulse close example residential applications SWITCH 7 AUTO CLOSE TIMER Defaul...

Page 12: ...vel as possible but still ensuring that it will slow down just before reaching the closed position INSTANT REVERSE DEVICE IRD The instant reverse device is an internal circuit that continuously monito...

Page 13: ...can be used with up to 15 rolling code remotes or passwords in HIGH security mode Alternately it can be used with up to 31 of any type remote in NORMAL security mode including any combination of roll...

Page 14: ...the right side of the gate operator frame Once turned off motor will not run and gate can be pushed by hand T R O U B L E S H O O T I N G Flip switch up for normal operation Flip switch down to diseng...

Page 15: ...DEVICE Gate will open when activated by an access control device When timer expires if used gate will close Figure 2 Terminal 5 is safety input Terminals 1 2 and 3 are open inputs DUAL DIRECTION AS E...

Page 16: ...AC XFMR MOTOR RED YEL YEL BLU ORG 24VDC REQULATED F4 F3 1 AMP DC F1 H BEAT BATTERY LOW AC POWER C O N T R O L B O A R D L AY O U T COMPONENT LOCATIONS Accessory power is 24VDC regulated rated at 500...

Page 17: ...BER DESCRIPTION 12 MS014 Siren 100 db 13 MS015 Transformer 110 220 VAC 24VAC 14 MS016 Duplex Outlet MS017 Bolt and Nut 4 Reducer 15 MS018 Idler Pulley Bolt Washer and Nut 16 MS019 120 VAC On Off Switc...

Page 18: ...18 OPERATOR NOTES...

Page 19: ...erating freely or not on level ground The warranty set forth above is entirely exclusive and no other warranty whether written or oral is expressed or implied LiftMaster inc specifically disclaims any...

Page 20: ...andard Time 6 00 A M TO 7 00 P M Monday through Friday 8 00 A M TO 4 30 P M Saturday www liftmaster com WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART NAME MODEL NUM...

Reviews: