CARTON INVENTORY

Before beginning your installation check that all components 
were provided and received undamaged. Refer to list below 
for factory provided parts.

 Description 

Qty.

  Safety Gate Brochure 

1

 Gate 

Bracket 

2

 Take-Up 

Bolt 

2

  Nickel Plated Chain #50 

1

  U-Bolt 2" 5/16-18 

4

  U-Bolt 3" 3/8-16 

4

  Square Head Set Screw 7/16-14 

4

  Hex Nut 1/2-13 

4

  Flange Nut 5/16"-18 

8

  Flange Nut 3/8"-16 

8

  Flat Washer 3/8" 

8

  Flat Washer 1/2" 

4

  Lock Washer 1/2" 

4

 Antenna 

1

 HARDWARE 

KIT 

 SL585/SL595 

(K77-34846)

IMPORTANT NOTES

•  BEFORE attempting to install, operate or maintain the operator, 

you MUST read and fully understand this manual and follow all 
safety instructions.

•  DO NOT attempt repair or service of your commercial door and 

gate operator unless you are an Authorized Service Technician.

T A B L E   O F   C O N T E N T S

OPERATOR SPECIFICATIONS

Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2
Operator Dimensions and Horsepower Chart . . . . . . . . . . . . . . .  3
UL325 Model Classifications  . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

OPERATOR WARNINGS

Safety Installation Information  . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Suggested Entrapment Protection Device Locations  . . . . . . . . .  6
Safety Precautions for Open Roller Gates. . . . . . . . . . . . . . . . . .  7
Warning Sign Placement  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

WIRING

Power Wiring Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8

INSTALLATION

Pad Mounting (SL585 only)  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9
Post Mounting (SL585 & SL595) . . . . . . . . . . . . . . . . . . . . . . .  10
Install Gate Bracket and Drive Chain. . . . . . . . . . . . . . . . . . . . .  11
Available Conduit Access for the Electrical Box  . . . . . . . . . . . .  12
On/Off Switch Power Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . .  12
Manual Disconnect   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  12

ADJUSTMENT

Limit Switch Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13
RPM Sensor Adjustment (Hall Effect). . . . . . . . . . . . . . . . . . . .  13
Gate System Test Procedures. . . . . . . . . . . . . . . . . . . . . . . . . .  13
Install Vent Plug  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14
UL325 Entrapment Protection  . . . . . . . . . . . . . . . . . . . . . . . 14-15
Control Board Illustration  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
Program Settings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
Control Connection Diagrams. . . . . . . . . . . . . . . . . . . . . . . . . .  17
Radio Reciever  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
Accessory Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
Earth Ground Rod Installation  . . . . . . . . . . . . . . . . . . . . . . . . .  21
Sequenced Access Management System  . . . . . . . . . . . . . . . . .  22

OPERATION AND MAINTENANCE

Operator Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23
Solenoid Actuated Brake. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
Friction Clutch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  24
Control Board Programming and Features . . . . . . . . . . . . . . 24-25
Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
Self-Regulating Heater Accessory. . . . . . . . . . . . . . . . . . . . . . .  28
Single Phase Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . .  29
Single Phase Schematic  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  30
Three Phase Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . .  31
Three Phase Schematic  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  32

REPAIR PARTS

Repair Parts - Model SL585 . . . . . . . . . . . . . . . . . . . . . . . . . . .  33
Illustrated Parts - Model SL585  . . . . . . . . . . . . . . . . . . . . . . . .  34
Repair Parts - Model SL595 . . . . . . . . . . . . . . . . . . . . . . . . . . .  35
Illustrated Parts - Model SL595  . . . . . . . . . . . . . . . . . . . . . . . .  36
Electrical Box  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37
Safety Accessories for Secondary Entrapment Protection  . . . .  38

NOTES

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  39

WARRANTY POLICY AND SERVICE

. . . . . . . . . . . . . . . .  40

When you see these Safety Symbols and Signal Words on the 
following pages, they will alert you to the possibility of 

SERIOUS 

INJURY or DEATH

 if you do not comply with the warnings that 

accompany them. The hazard may come from something 
mechanical or from electric shock. Read the warnings carefully.

When you see this Signal Word on the following pages, it will 
alert you to the possibility of damage to your gate and/or the gate 
operator if you do not comply with the cautionary statements that 
accompany it. Read them carefully.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

WARNING

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

WARNING

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

Mechanical

Electrical

Summary of Contents for LiftMaster Professional SL585

Page 1: ...ox cover Installation Date__________________ 2 YEAR WARRANTY MODELS SL585 AND SL595 ARE FOR VEHICULAR PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE MODEL SL585 HEAVY DUTY SLI...

Page 2: ...stall Vent Plug 14 UL325 Entrapment Protection 14 15 Control Board Illustration 15 Program Settings 16 Control Connection Diagrams 17 Radio Reciever 18 19 Accessory Wiring 19 20 Earth Ground Rod Insta...

Page 3: ...Gate Width 45 ft 13 7 m Maximum V Track Gate Width 35 ft 10 7 m 1 HP Motor Maximum Gate Speed 12 sec 30 5 cm sec Maximum Gate Weight 1700 lbs 771 1 kg Maximum Cantilever Gate Width 35 ft 10 7 m Maximu...

Page 4: ...eans of entrapment protection Both primary and secondary entrapment protection methods must be designed arranged or configured to protect against entrapments in both the open and close directions of g...

Page 5: ...t be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily acc...

Page 6: ...es for Close Cycle 4 1 2 m Typical 4 1 2 m Typical Open Edge Photo Eyes for Open Cycle Run Twisted Wire from Loop to Operator STREET COMPLEX OR PARKING LOT Gate 1 Interrupt Safety Loop Photo eye for o...

Page 7: ...both inside and outside of a vehicular horizontal slide gate Non contact sensors such as photo eyes must protect during both open and close gate cycles Injuries occur when people put their hands and a...

Page 8: ...f the power disconnect should be visible and clearly labeled ALL power and control wiring MUST be run in separate conduit BEFORE installing power wiring or control stations be sure to follow all speci...

Page 9: ...e 2 2 Locate electrical conduit as required prior to pouring concrete 3 Pour concrete pad 4 Secure operator Figure 3 to the concrete pad using four 1 2 concrete anchors not provided Figure 1 Figure 2...

Page 10: ...o pouring concrete 3 Secure operator to posts using four 3 U bolts and hardware provided Figure 3 Figure 2 14 35 6 cm Min Ground Level Depth As Required By Local Codes or Below Frost Line 3 7 6 cm Out...

Page 11: ...ain slack for every 10 3 1 m of chain length Do not overtighten chain NOTE ABOUT SOME TYPES OF CANTILEVER GATES With some cantilever gates over 20 6 1 m long you may need to add a brace along the leng...

Page 12: ...ns inside the disconnect switch electrical box Refer to electrical wiring diagrams on pages 27 30 MANUAL DISCONNECT 115VOLT 1 PH USE COPPER CONDUCTO R ONLY 115VOLT 1 PH USE COPPER CONDUCTOR ONLY 115V...

Page 13: ...y to adjust the sensor for correct alignment To do so please perform the following steps 1 The sensor must be centered over the magnet wheel Adjust with horizontal screws 2 The sensor must be level 3...

Page 14: ...the gate is closing will have no effect Terminals 10 5 Obstruction While Closing Edge Photo Eye Input Edge Input See Programming Section on page 15 This input will reverse a closing gate to the open l...

Page 15: ...he gate to the open limit when activated during the close cycle The entrapment is not cleared at the limit and the timer to close will be disabled The timer to close may be enabled by activating the i...

Page 16: ...N SAVE TTC ON S1 RT LT SW SL RT LT SW SL 1 2 3 4 ON SAVE TTC ON S1 1 2 3 4 ON SAVE TTC ON S1 RT LT SW SL RT LT SW SL Factory Default TIMER TO CLOSE ENABLED SWING GATE SLIDE GATE TIMER TO CLOSE DISABLE...

Page 17: ...guidelines presented throughout the manual Installation device instructions Always follow the instructions provided by the manufacturer when installing and adjusting any control device If these instru...

Page 18: ...To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with remote controls Activat...

Page 19: ...eration is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesi...

Page 20: ...any additional surge protection MASTER SECOND SYSTEMS Dual Gate Communications The control board is capable of running the operator in a master or second mode depending on S4 switch setting Before in...

Page 21: ...ground rod must be located within 3 feet from the gate operator Use the proper type earth ground rod for your local area The ground wire must be a single whole piece of wire Never splice two wires for...

Page 22: ...pair of slide swing gate operator The design of this gate system balances the demands of speed during high traffic periods with security during low traffic periods Barrier gates typically have the fa...

Page 23: ...rea Clean the operator as needed 6 It is suggested that while at the site voltage readings be taken at the operator Using a Digital Voltmeter verify that the incoming voltage to the operator it is wit...

Page 24: ...uction the clutch will slip 1 Loosen set screws of torque adjustment nut on the gear reducer output shaft 2 Back off torque nut until there is very little tension on the Belleville washers 3 Tighten t...

Page 25: ...ult Control Input 6 Loss of communications Removal of between master and problem second during run mode On No Motor not learned Completion Flash of Motor Learn Routine Hard inputs include open overrid...

Page 26: ...he operator This voltage should be within 5 of 24Vac If the high voltage power is good and the low voltage power is bad check to make sure the circuit fuse is not tripped and that the correct primary...

Page 27: ...The brake should disengage when the contactor activates and engage when the contactor releases Both LEDs will indicate the activation of entrapment protection devices on terminals TB1 9 and TB1 10 on...

Page 28: ...R AT O R S H E AT E R W I R I N G D I A G R A M F O R 2 0 8 2 3 0 4 6 0 A N D 5 7 5 V O P E R AT O R S HEATER REPLACEMENT PARTS PART NUMBER DESCRIPTION QTY 21 15453 1 Transformer 100VA with 3 2A fuse...

Page 29: ...B A A1 A2 A1 A2 RPM SENSOR GL CONTROL BOARD 24VAC IN 24VAC COMMON SOFT OPEN NC B LIMIT CONTACTOR B A LIMIT CONTACTOR A RPM IN RPM SUPPLY RPM GND RADIO COMMAND SHADOW 24VDC CLOSE STOP SOFT OPEN HARD OP...

Page 30: ...B NC C YEL BLK Y BK GY TB2 BL Y PU GY BL Y PU 1 3 8 5 4 2 OL BK BK BK BK BL BK BL BK 115V BRAKE SOLENOID 115V CONNECTION 230V BRAKE SOLENOID 208 230V CONNECTION BL BK BL BK 4 5 2 3 8 1 LOOP WIRING TB...

Page 31: ...RD WH PU P W Y BK GN Y BK Y BK WH BRN BRN OR GN GY OR BK WH RD BK BK BL YE GY BRN GY BRN OR Y BK GN Y BK YE YE BL BL BRN PU OR BL BL BK BK YE YE YE RD RD L3 BK BK FACTORY INSTALLED RADIO 40 32351G 3...

Page 32: ...32 T H R E E P H A S E S C H E M AT I C...

Page 33: ...0 Alarm kit Complete with Alarm spacer and faston K9 K75 18493 Chain guide kit K10 653509 Optional diagonal brace kit NOT SHOWN 71 6532449 Heater kits Optional 115 575V Operators 71 6532448 Heater kit...

Page 34: ...5 34842 10 2 1 K1 71 B120 71 B240 71 B575 K2 K75 10177 6 K4 K75 34824 4 3 4 3 K3 K75 34828 K6 K75 34790 K7 K75 34791 K8 K29 32410 8 K9 K75 18493 K10 653509 I L L U S T R AT E D P A R T S M O D E L 5 8...

Page 35: ...larm kit Complete with Alarm spacer and faston K7 K75 18493 Chain guide kit NOT SHOWN 71 6532449 Heater kits Optional 115 575V Operators 71 6532448 Heater kits Optional 208 230 460V Operators K50 1842...

Page 36: ...AT E D P A R T S M O D E L 5 9 5 3 6 12 13 4 5 6 1 2 7 8 9 11 K3 K75 12858 K1 71 B120 71 B240 71 B575 K2 K75 18618 K4 K75 18620 K6 K29 32410 K5 K72 18615 19 18 18 16 17 15 10 14 K7 K75 18493 312HM Rec...

Page 37: ...erload 10 AMP SL585 50 11 SL595 50 11 SL585 150 21 SL595 150 21 25 2015 Overload 15 AMP SL585 100 11 SL595 100 11 25 2025 Overload 25 AMP SL585 150 11 SL595 150 11 Non stocked item Please allow additi...

Page 38: ...9 m Maximum Range 24V ac dc SENSING EDGES MODEL DESCRIPTION VOLTAGE G65MG0204 Miller MG020 2 wire electric edge for gates Sensitized on three sides 24V ac dc Requires mounting channel 4 1 2 m long G65...