10
Preparing the Installation
Doc 01-G0665
Rev C
Single Phase
3 Phase
115 VAC
230 VAC
230 VAC
460 VAC
575 VAC
AWG
Maximum wire length in feet for 1/3 HP motor
6
700
3,100
4,750
14,225
35,550
8
450
1,950
3,000
8,975
22,425
10
275
1,225
1,900
5,650
14,075
12
175
775
1,175
3,525
8,825
AWG
Maximum wire length in feet for ½ HP motors
6
475
2,075
2,850
14,225
17,775
8
300
1,300
1,800
8,975
11,225
10
200
825
1,125
5,650
7,050
12
125
525
725
3,525
4,425
AWG
Maximum wire length in feet for ¾ HP motors
6
325
1,250
2,050
7,125
11,850
8
225
800
1,300
4,500
7,475
10
150
500
825
2,825
4,700
12
100
325
525
1,775
2,950
AWG
Maximum wire length in feet for 1 hp motors
6
250
950
1,425
5,700
8,900
8
150
600
900
3,600
5,625
10
100
375
575
2,275
3,525
12
75
250
375
1,425
2, 225
Table 5: Power Wiring Chart
System Features
ACTIVITY LED
Steady indication when gate is at either open
or close limit.
1 second flash when gate is off a limit in
normal operation.
2 second flash when an entrapment has
occurred.
AUDIBLE WARNING DEVICE
If the operator should have a second inherent
obstruction in sequence with the first; (i.e. back to
back), the sounder will activate
.
Also, the sounder can
be programmed to come on 3 seconds prior to gate
movement, and remain on during gate movement.
0 1 -G 0 6 6 5 F1 5
Figure 3
THREE BUTTON CONTROL (SEQUENCE OF OPERATION)
Open, stop, close. Stop will override all other functions. If closing, Open will cause the operator to
stop and reverse to full open. If gate is at its fully opened position, the Close function will cause
the gate to close.