Mount Receiver

Additional UltraRX Receivers

NOTE:

This step applies only if more than one

Receiver is being used.

Up to four Receivers can be used. Each Receiver will
need a different Identity. Set the Identity of the
Receivers by changing the Dipswitches as shown in
the chart below. The Default Identity is 1.

Receiver ID

Switch #2

Switch #3

1

OFF

OFF

2

ON

OFF

3

OFF

ON

4

ON

ON

Step 2:

Connect power to Receiver (see 

ULTRX900R manual). 

Step 3:

Within 15 seconds, enter the Master PIN

Number on the main Keypad:

The Keypad will beep twice and Receiver Relay will
buzz indicating programming is successful.
Repeat for additional Receivers.

Followed by Receiver Identity:

2

3

4

OR

OR

Step 1:

On the Receiver, place Dipswitch #1 to the

ON position.

Step 2:

Connect power to Receiver (see 

ULTRX900R manual). 

Step 3:

Within 15 seconds, enter the Master PIN

Number on the main Keypad:

Then:

1

The Keypad will beep twice and Receiver Relay will
buzz to indicate programming is successful. 
If and error tone is heard, the memory on the
Receiver will need to be cleared by holding down the
Learn button until LED starts to flash.

Set-Up with UltraRX Extreme
Range Receiver (ULTRX900R)

Step 1:

Mount the Receiver

with the Terminal Block at the
bottom and the antenna
hanging straight down.

NOTE:

Metal surfaces can

shorten the range of the
Receivers. If mounting on a
metal surface and long range is
required, use a non-metallic
spacer to move the Receiver
away from the metal surface.

Step 2:

Connect the Relay Output of Receiver to the

gate or door. To connect to a Door Strike or Magnetic
Lock, see diagrams below.

1           2          3           4         5           6           7          8           9        10        11         12        13

1

3

2

4

5

6

7

8

9 10 11

+

-

N

/O

COM

N

/C

Door 
Strike

Transformer/
Po

w

er S

u

pply

Open/
Close

12 13

Door Strike- Normally Open (N/O) Connection

DC

AC

Optional external po

w

er 

inp

u

t 10-24 Vac or DC

1

3

2

4

5

6

7

8

9 10 11

+

-

Magnetic 
Lock

Transformer/
Po

w

er S

u

pply

12 13

Magnetic Lock- Normally Closed (N/C) Connection

DC

AC

Optional external po

w

er 

inp

u

t 10-24 Vac or DC

N

/O

COM

N

/C

Open/
Close

Proceed to 

Mount Keypad

.

1

2

3

4

5

6

7

8

9

*

0

#

Cancel

Step 1:

On the Receiver, place Dipswitch #1 to the

ON position.