There are 2 different ways to close the gate (entering or exiting):
1. Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave).
2. Interrupt Loop; clearing the Inside Interrupt Loops cause the gates to close (Master or Slave).
NOTE:
To ensure gate closure, set Reclose Timer =ON in both Master and Slave
INPUT CONNECTIONS:
(for more details, refer to Part 2, Paragraph L, Connecting Input Wiring)
•
Master and Slave units require their own separate inputs.
•
If Radio inputs are used in both units, each requires its own transmitter and entry code.
MASTER
UNIT SWITCH S1 SETTINGS AND INPUTS
Gate
Type
SLIDE
ACTION
(Reclose)
TIMER
RETRY
ATG
MASTER
TRAP
Operator
Inputs
Trap
Unit
Option
n
Unit
Option
n
Unit
Option
n
ON ON ON
Unit
o
SLAVE
UNIT SWITCH S1 SETTINGS AND INPUTS
Trap
Unit
Option
n
Unit
Option
n
Unit
Option
n
No Effect
OFF
OFF
Unit
o
n
:
Master and Slave units can have different Reclose Timer settings.
o
:
Inputs affect one gate operator only, so connect inputs separately to each gate operator.