32 of 53
Doc 6001242 (01-20273)
Rev C
•
A continuous FIRE input in either gate opens both gates and holds them open.
•
A continuous Manual STOP in either gate stops both gates.
There are 2 different ways to close the gate after entering or exiting:
1. Reclose Timer: When the Reclose Timer expires, the gates close automatically (Master or Slave).
2. ATG and Interrupt Loop: When ATG is ON, clearing the Inside Interrupt Loop causes the gate to
close (Slave unit only).
INPUT CONNECTIONS:
(for more details, refer to Part 2, Paragraph L, Connecting Input Wiring)
MASTER
UNIT SWITCH S1 SETTINGS AND INPUTS
Gate
Type
SLIDE
ACTION
(Reclose)
TIMER
RETRY
ATG
MASTER
TRAP
Operator
Inputs
Tandem
Unit
Option
n
Unit
Option
n
Unit
Option
n
OFF ON ON
o
SLAVE
UNIT SWITCH S1 SETTINGS AND INPUTS
Tandem
Unit
Option
n
Unit
Option
n
Unit
Option
n
Unit
Option
OFF OFF
o
n
:
Master and Slave units can have different settings.
o
:
Exit, Radio, Cycle, Fire, and Manual Stop inputs affect both gate operators, so connect inputs to one unit only.