46 of 53
Doc 6001242 (01-20273)
Rev C
SHADOW LOOP Activation prevents the gate from opening or closing so the gate won't hit a
vehicle. If the gate is already moving, or if the gate is not fully opened or
closed, this input has no effect.
INSIDE/OUTSIDE INTERRUPT LOOP DETECTOR (TB16)
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "ON"
Gate fully open or closed:
activation prevents the gate from moving.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing
: activation halts the gate. When the Interrupt
Loop clears, an opening gate closes and a closing gate resumes its course.
INSIDE
INTERRUPT LOOP with SLIDE "OFF" and ATG "OFF"
Gate fully open or closed:
activation prevents the gate from moving.
Gate opening or closing
: activation halts the gate. When the Interrupt
Loop clears, the gate resumes its course.
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "ON"
Gate fully open or closed:
activation prevents the gate from closing.
When the Interrupt loop clears, the gate begins closing.
Gate opening or closing
: activation halts a closing gate. When the
Interrupt Loop clears, an opening gate closes and a closing gate resumes its
course.
INSIDE
INTERRUPT LOOP with SLIDE "ON" and ATG "OFF"
Gate fully open or closed:
activation prevents the gate from closing only.
Gate opening or closing:
activation fully opens a closing gate and starts
the Reclose Timer if timer is "ON".
OUTSIDE
INTERRUPT LOOP with ATG "OFF"
Gate fully open or closed:
activation prevents the gate from closing only.
Gate opening or closing:
activation fully opens the closing gate and starts
the Reclose Timer if timer is "ON".
OUTSIDE
INTERRUPT LOOP with ATG "ON"
Gate fully open or closed:
activation prevents the gate from closing only.
Gate opening or closing:
activation prevents the gate from closing. When
the interrupt loop clears, the gate begins closing.
INTERRUPT BAR INPUTS (TB11)
INTERRUPT BAR Activation fully opens a closing gate and stops an opening gate. If RETRY
is ON, the gate waits 30 seconds, then tries to resume. The gate will re-try
twice before faulting out. If the Interrupt Bar remains active for more than 30
seconds, the gate will not retry.