13
When properly installed, opener will provide high performance with
a minimum of maintenance. The opener does not require additional
lubrication.
Limit and Force Settings:
These settings must be checked and
properly set when opener is installed. Weather conditions may cause
some minor changes in the door operation, requiring some
re-adjustments, particularly during the first year of operation
.
Refer to
Setting the Limits and Force
on page 5. Follow the
instructions carefully and
repeat the safety reverse test after
any adjustment.
Remote Control:
The remote control may be secured to a car sun
visor with the clip provided. Additional remotes can be purchased at
any time for use in all vehicles using garage. Refer to Accessories.
Any new remotes must be programmed into the opener.
Remote Control Battery:
The lithium batteries should produce power
for up to 5 years. If transmission range lessens, replace battery.
To Change Battery:
To replace batteries, use the visor clip or
screwdriver blade to pry open the case. Insert batteries
positive side
up
. To replace cover, snap shut along both sides. Do not dispose of
the old battery with household waste. Take batteries to a proper
disposal center.
CARE OF YOUR OPENER
OPERATION OF YOUR OPENER
Your opener can be activated by any of the following devices:
•
The Lighted Door Control Button.
Hold the button down until door
starts to move.
•
The Outside Keylock or Keyless Entry System
(if you have
installed either of these accessories).
•
The Remote Control Transmitter.
Hold the push button down until
the door starts to move.
Opening the Door Manually:
Door should be fully closed if possible. Weak or broken springs
could allow an open door to fall rapidly. Property damage or
serious personal injury could result.
The door can be opened manually by pulling the release handle down
and back (toward the opener). To reconnect the door, pull the release
handle straight down.
Do not use the manual release handle to pull the door opener
or closed.
When the Opener is Activated by Remote Control or Lighted Door
Control Button:
1. If open, the door will close. If closed, the door will open.
2. If closing, the door will stop.
3. If opening, the door will stop (allowing space for entry and exit of
pets and for fresh air).
4. If the door has been stopped in a partially open or closed position, it
will reverse direction.
5. If an obstruction is encountered while closing, the door will reverse.
6. If an obstruction is encountered while opening, the door will reverse
and stop.
7. The optional Protector System™ uses an invisible beam which,
when broken by an obstruction, causes a closing door to open
and prevents an open door from closing. It is STRONGLY
RECOMMENDED for homeowners with young children.
Allow a 15 minute cooling period after 5 continuous operations
of the opener.
The opener light
will turn on: 1. when opener is initially plugged in;
2. when the power is briefly interrupted; 3. when the opener is
activated.
The light turns off automatically after 2-1/2 minutes. Bulb size is
24V/21W maximum.
Input Voltage...................230-240 VAC, 50Hz
Max. Pull Force ..............600N
Power .............................100W
Standby Power ...............5,5W
Normal Torque ................5Nm
Motor
Type ................................DC gearmotor permanent lubrication
Drive Mechanism
Drive ...............................Chain/belt with two-piece trolley on
steel rail.
Length of Travel..............Adjustable to 2,3m (7-1/2 feet)
Travel Rate .....................5"-7" (127-178mm) per second
Lamp...............................On when door starts, off 2-1/2 minutes
after stop.
Door Linkage ..................Adjustable door arm. Pull cord trolley release.
Safety
Personal .........................Push button and automatic stop in
down
direction. Push button and automatic stop in
up
direction.
Electronic ........................Automatic force adjustment
Electrical .........................Transformer overload protector and low
voltage push button wiring.
Limit Device ....................Optical RPM/Passpoint detector.
Limit Adjustment .............Electronic, Semi and Fully Automatic.
Start Circuit .....................Low voltage push button circuit.
Dimensions
Length (Overall)..............3.2m (122-1/2")
Headroom Required .......30mm
Hanging Weight ..............14.5kg (32 lb)
Receiver
Memory Registers ..........12
Operating Frequency......433.92MHz
SPECIAL NOTE:
Liftmaster strongly recommends that the protector
system be installed on all garage door openers.
SPECIFICATIONS
114A3356