OPEN
CLOSE
STOP
Half the Height of the Door
NEVER
run Control wiring
in
same conduit
as the
Power wiring!
Edge Sensor
Approximately 5 Feet
6" max
above the
floor.
White/Black
White
Push and Release to
Open
(without Mid Stop programming)
Push and Release to
Stop
Push and
Hold
to
Close
CONTROL WIRING
USE COPPER WIRE ONLY
TIMER
MID
MRT
TIMER
MID
MRT
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
Open Mid Stop Programming
1.
Close the Door.
6.
Turn selector back to selected wiring type.
3.
Press and release the
MID
button.
2.
Turn selector to
PROG
.
OPEN
CLOSE
STOP
D20
D21
D13
11
11
9
8
20 AWG or Greater
24VAC
24VAC
Timer Defeat
Common
MAS
Maintenance Alert LED
LMEP
Edge
Open
Close
Stop
Common
SBC
14
1
2
3
4
5
6
7
8
9
10 11 12 13
7
6
5
4
4
4
10
The
OPEN LED
will flash once for every 1 sec.
The
CLOSE LED
will flash once for every 15 sec.
Timer-to-Close Programming
Timer automatically closes door after a preset time.
1.
Close the Door.
5.
Press and release the
OPEN
button once for every 1 seconds.
Press and release the
CLOSE
button once for every 15 seconds.
TIMER
MID
MRT
3.
Press and release the
TIMER
button.
TIMER
MID
MRT
6.
Press and release the
TIMER
button to complete programming.
2.
Turn selector to
PROG
.
4.
Press and release the
STOP
button to clear the timer.
OPEN
CLOSE
STOP
D20
D21
D13
Example:
Push CLOSE + Push OPEN + Push OPEN =
17 seconds total
(15 seconds) (1 second)
(1 second)
OPEN
CLOSE
STOP
D20
D21
D13
The mid stop feature is to open the door to a preset point prior to the fully open position.
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
8.
Turn the selector dial back
to the desired wiring type.
MAS Programming (Maintenance Alert System)
MAS
6.
Press the
OPEN
button once for
every
5,000 Cycles
increments.
Press
the
CLOSE
button once for
every
3 Month
increments.
Press
the
STOP
button once to
Clear the MAS Setting.
OPEN
CLOSE
STOP
D20
D21
D13
2.
Close the Door.
1.
The MAS assists the installing dealer in setting
up a routine maintenance program. Once
programmed, the MAS notifies the end user
(with a flashing LED on the 3 button station)
when a preset number of cycles/months has
elapsed and scheduled maintenance is due.
4.
Press and release the
MAS
button.
5.
Press the
STOP
button once
to clear the MAS counter.
3.
Turn the selector dial
to
PROG
.
MAS
OPEN
CLOSE
STOP
D20
D21
D13
OPEN
CLOSE
STOP
D20
D21
D13
OPEN
CLOSE
STOP
D20
D21
D13
7.
Turn selector to T, TS or FSTS wiring types.
NOTE:
Must have at least one LiftMaster Monitored
Entrapment Protection (LMEP) device installed.
Follow ALL national and local electrical codes
OPTN
OPTN
LiftMaster Monitored Entrapment Protection (LMEP)
is required for most programmable settings.
Thru-Beam Photoelectric Sensors (Shown)
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
OPTN
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
OPTN
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
OPTN
E2
T
TS
FSTS
DIAG
PROG
D1
B2
C2
OPTN
4.
Press the
OPEN
button, wait until the door reaches the desired
mid stop height, then press and release the
STOP
button.
5.
Press and release the
MID
button to complete programming.
7.
Press the
MAS
button to
complete the programming.
The on board
LED
will flash back
the programmed settings. The
OPEN LED
will flash once for every
5,000 cycles. The
CLOSE LED
will
flash once for every 3 months.
Remote Controls
Built in 3-channel, Security
2.0
TM
radio receiver
that allows you to add up to 90 remote control
devices and up to 30 keyless entry devices.
E2
T
TS
FSTS
DIAG
PROG
D1
C2
B2
Factory Setting is C2*
Board Selector Dial
OPTN
*See installation manual for full description
of modes.