background image

The Protector System must be installed

when the force at the edge of the closing

door force exceeds 400N (40kg). Excessive

force will interfere with the proper operation of

the Safety Reverse System or damage the

garage door.
Permanently

fasten

the

caution

label

adjacent to the wall-mounted door control

control button as a reminder of safe operating

procedures.

Disengage all existing garage door locks to

avoid damage to garage door.
Install the lighted door control button (or any

additional push buttons) in a location where

the garage door is visible, at a height of at

least 1.5m and out of the reach of children.
Do not allow children to operate push

button(s) or remote control(s). Serious

personal injury from a closing garage door

may result from misuse of the opener.
Activate opener only when the door is in

full view, free of obstructions and opener

is properly adjusted. No one should enter

or leave the garage while the door is in

motion. Do not allow children to play near

the door.
Use manual release only to disengage the

trolley and, if possible, only when the door is

closed. Do not use the red handle to pull

the door open or closed.

Disconnect electric power to the garage

door opener before making repairs or

removing covers.

This product is provided with a power supply

cord of special design which, if damaged,

must be replaced by a power supply cord

of the same type

; such a power supply cord

may be obtained and fitted by a specialist.

Failure to comply with the following instructions may result in serious personal injury or property damage.

• Read these instructions carefully

• The garage door opener is designed and tested to offer reasonable safe service provided it is installed

and operated in strict accordance with the instructions in this manual.

These safety alert symbols mean Warning – a personal safety or property damage instruction. Read these
instructions carefully.

Warning: If your garage has no service entrance door, Model CM1702 Outside Quick Release must be installed. This accessory
allows manual operation of the garage door from outside in case of power failure.

Keep garage door balanced. Do not let the

garage door opener compensate for a binding

or sticking garage door. Sticking or binding

doors must be repaired. Garage doors, door

springs, cables, pulleys, brackets and their

hardware are under extreme tension and can

cause serious personal injury. Do not

attempt to loose, move or adjust them. Call

for garage door service.

Do not wear rings, watches or loose

clothing while installing or servicing a garage

door opener.

To avoid serious personal injury from

entanglement, remove all ropes connected

to the garage door before installing the door

opener.

Installation and wiring must be in compliance

with your local building and electrical codes.

This is a class 2 double insulated product,

connection to earth is not required or

provided.

Lightweight doors of fiberglass, aluminum

or steel must be substantially reinforced

to avoid door damage. (See page 3.) The

best solution is to check with your garage

door manufacturer for an opener installation

reinforcement kit.
The safety reverse system test is very
important. 
Your garage door MUST reverse
on contact with a 40mm obstacle placed on
the floor. Failure to properly adjust the opener
may result in serious personal injury from a
closing garage door. Repeat the test once a
month and make any needed adjustments.

This unit should not be installed in a damp
or wet space.

Door must not extend over public byway
during operation.

Start by Reading These Important Safety Instructions

2

Contents

Page

Illustration

Safety Rules . . . . . . . . . . . . . . . . . . . . . . . 2
Before you Begin . . . . . . . . . . . . . . . . . . . 3
Door Types . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . 1
Tools Required . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . 2
Hardware Provided . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . 3
Completed Installation . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . 4
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . .5 . . . . . . . . . . . . . 5-11
Installation . . . . . . . . . . . . . . . . . . . . . . 7-12 . . . . . . . . . . . . 12-21
Programming your Opener & Remote . 13 . . . . . . . . . . . . . . . 22
Programming your Keyless Entry . . . . .14 . . . . . . . . . . . . . . .23
Using the Wall-Mounted Door Control .14 . . . . . . . . . . . . . . .24

Adjustment . . . . . . . . . . . . . . . . . . . . . . . 15 . . . . . . . . . . . . 25-26
Test the Safety Reversal System . . . . . .15 . . . . . . . . . . . . .27
Install the Protector System

(Optional) . . . . . . . . . . . . . . . . . . . . . . . . 16 . . . . . . . . . . . . 28
Special Features of the MT60 . . . . . . . .16 . . . . . . . . . . . . 29
Accessories . . . . . . . . . . . . . . . . . . . . . . .17 . . . . . . . . . . . . 30
Replacement Parts . . . . . . . . . . . . . . 18-19 . . . . . . . . . 31-32
TROUBLE SHOOTING

. . . . . . . . . . . . . 20

Care of your Opener . . . . . . . . . . . . . . . 21
Maintenance of your Operator . . . . . . . 21
Operation of your Opener . . . . . . . . . . . 21
Specifications . . . . . . . . . . . . . . . . . . . . . 21

Summary of Contents for Merlin MT60

Page 1: ...Instruction Manual for MT60 Sectional and Tilt Garage Door Motor Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Chamberlain New Zealand Ltd P O Box 100 221 North Shore 0745 www chamberl...

Page 2: ...e installed This accessory allows manual operation of the garage door from outside in case of power failure Keep garage door balanced Do not let the garage door opener compensate for a binding or stic...

Page 3: ...he Protector System 30 8 required See your dealer Tools Required 2 3 Before You Begin 1 Look at the wall or ceiling above the garage door The header bracket must be securely fastened to structural sup...

Page 4: ...Spring 20 Flat Washer 21 Stop Bolt Hardware Provided 3 1 Header Sleeve 2 Idler Pulley Bracket 3 Trolley 4 Rail 5 Chain 6 Hanging Bracket 7 Power Cord 8 Opener 9 Light Lens 10 Manual Release Rope Handl...

Page 5: ...inner trolley 2 into back opener end of rail assembly 3 be sure to insert idler pulley bracket as shown Arrow on trolley 7 must face toward front header end of rail 4 Push idler pulley bracket toward...

Page 6: ...n bolts securely The opener sprocket teeth must engage the chain CAUTION Use only those bolts mounted in the top of opener Use of any other bolts will cause serious damage to opener 4 7 6 3 Attach Spr...

Page 7: ...m You can attach the header bracket either to the header wall 1 or to the ceiling 3 Follow the instructions which will work best for your particular requirements With the door closed mark the vertical...

Page 8: ...to vertical center and horizontal lines created in step 12 for proper placement of header bracket A Wall Mount Center the header bracket 1 on the vertical center line 2 with the bottom edge of the hea...

Page 9: ...erent Hanging brackets 1 should be angled Figure A to provide rigid support On finished ceilings Figure B attach a sturdy metal bracket not supplied 4 to a structural support before installing the ope...

Page 10: ...fuser up until engaged Replace burnt out bulbs with heavy duty light bulbs 19 1 2 A 0 100mm B 150 250mm 3 4 7 6 2 1 4 5 3 A 4 B 7 6 A B 1 4 C 1 2 3 3 1 2 4 10 1 2 1 2 1 2 3 3 1 2 4 4 1 4 3 Fasten Door...

Page 11: ...ect the inner and outer trolley Slide the outer trolley back toward the opener and join the curved arm 2 to the connector hole in the trolley 8 with clevis pin 6 It may be necessary to lift the door s...

Page 12: ...is visible away from door and door hardware and out of the reach of children Mount at least 1 5 m 5 feet above the floor Serious personal injury from a moving garage door may result from misuse of ope...

Page 13: ...the Multi Function Door Control 4 Press and hold the button on the hand held remote that you wish to operate your garage door 4 5 While holding the remote button press and hold the LIGHT button on th...

Page 14: ...are held 7 Release buttons when the opener light blinks It has learned the code If the light bulb is not installed two clicks will be heard LOCK LIGHT LOCK LIGHT 24 Optional Motion Detecting Control P...

Page 15: ...travel to the UP open position The LED 3 indicator light will stop flashing when the force has been learned The door must travel through a complete cycle UP and DOWN in order for the force to be set p...

Page 16: ...es The force as measured on the closing edge of the door should not exceed 400 N 40kg If the closing force is more than 400 N the Protector System must be installed After opener has been installed and...

Page 17: ...Remote Control 6 Model C840 Keyless Entry System 7 Model C98 Motion Detecting Control Panel 8 Model 760 Outside Keylock 9 Model CM1702 Outside Quick Release 10 Model C77 The Protector System 11 Model...

Page 18: ...178B69 41B4616 4A1008 1 2 109A46 1 83A11 41A5643 3 12VDC Pb Cd Hg 12B380 12C778 41A5800 12C855 183D177 183D178 41A5887 001A5060 15 10A20 216A206 31D536 31D533 41A5843 41A5799 210C42 12C777 144C77 146...

Page 19: ...41A5735C 111A79 204C0161 2 41D577 108C82 41A5908 41A5797 158A49 031D0587 32 19...

Page 20: ...steps 25 and 26 Repeat the safety reverse test after the adjustment is complete 11 Opener light does not turn on Replace light bulb 24V 21W maximum Replace burned out bulbs with rough service light bu...

Page 21: ...and back toward the opener To reconnect the door pull the release handle straight down Do not use the manual release handle to pull the door opener or closed When the Opener is Activated by Remote Con...

Page 22: ...Unit that it is free from defects in material and or workmanship for a period of 2 YEARS from the date of first purchase from the Seller Please retain your proof of purchase in the unlikely event you...

Reviews: