en-5
Separate table for setting the operating modes
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Gate closed:
1. impulse opens gate 1
(pedestrian), the next one stops, the
next one closes, the next one stops,
the next one opens etc.
Impulse during closing stops
the gate
Impulse during closing stops the
gate
Impulse during opening stops
the gate
Impulse during opening stops the
gate
Impulse during the rest
closes the gate immediately
Impulse during the rest closes the
gate immediately
Standard
Standard &
no self-hold (hold to run) for closing
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Gate open:
Permanent signal required for
closing, letting go stops
Impulse during closing stops
the gate
Radio disabled, safety equipment
disabled
Impulse during opening stops
the gate
Impulse during the rest closes
the gate immediately
DIP1
ON
ON
OFF
DIP2
ON
OFF
OFF
DIP3
OFF
ON
OFF
Impulse transmitter/channel 1
Impulse transmitter/channel 2
No self-hold (hold to run)
Gate closed:
Permanent signal
required, letting go stops
Gate open:
Permanent signal required,
letting go stops
Radio disabled, safety
equipment disabled
Radio disabled, safety equipment
disabled
ACCESSORIES
PHOTOCELLS (OPTIONAL)
The photocells are for safeguarding the gate and must be used. The
fitting location depends on the gate’s design. EN12453 specifies that
a pair of photocells must be installed at a height of 200 mm and
activated to “Close”; a second pair must be installed at a height of
200 mm and activated to “Open”. A third pair of photocells can be
optionally installed and activated to “Close” and “Open”. The
photocells consist of a transmitter and a receiver and must be
opposite each other. The housing of the photocell (plastic) can be
opened using a screwdriver. The photocell is mounted on the wall
using small screws and wall plugs. It is possible to use two different
photocell systems (see Dip switch description). To enable the
“Automatic Closing” function, the Chamberlain failsafe photocell must
be installed. A combination of photocells is not possible. The
Chamberlain failsafe system (2-cable system) has small LEDs (light)
that can be seen from the outside on both sides to indicate the status
of the photocell. Two Chamberlain failsafe photocell models are
available. The one model is ideal for walls lying opposite. The other
model is ideal for the inside of the gate, because fittings are already
available.
Diagnosis at the Chamberlain failsafe photocell
LED constant = OK
LED flashes = photocell disables control board
LED off = no current, incorrect connection or polarity
Diagnosis on the control board
LED off = OK
LED on constantly = control board disables
LED flashes = OK no photocell connected
Cable cross-section: 0.5 mm
2
or more.
Voltage: 12/24 volts AC/DC.
Do not use any fixed copper lines. Do not lay any 230 volt cables in
parallel and do not lay any 2 cables in the same cable trunking.
open/öffnen/ouvrir/open
close/schliessen/fermer/sluiten
close/schliessen/
fermer/sluiten
open/öffnen/
ouvrir/open
771EML