22
Install the Protector System
®
OPTION B
PRE-WIRED INSTALLATION
1. Cut the end of the safety reversing sensor wire, making sure there is enough wire
to reach the pre-installed wires from the wall.
2. Separate the safety reversing sensor wires and strip 7/16 inch (11 mm) of
insulation from each end. Choose two of the pre-installed wires and strip 7/16
inch (11 mm) of insulation from each end. Make sure that you choose the same
color pre-installed wires for each sensor.
3. Connect the pre-installed wires to the sensor wires with wire nuts making sure
the colors correspond for each sensor. For example, the white wire would
connect to the yellow wire and the white/black wire would connect to the purple
wire.
4. At the garage door opener, strip 7/16 inch (11 mm) of insulation from each end
of the wires previously chosen for the safety reversing sensors. Twist the like-
colored wires together.
5. Insert the wires connected to the white safety sensor wires to the white terminal
on the garage door opener. Insert the wires that are connected to the white/black
safety sensor wires to the grey terminal on the garage door opener.
Safety reversing
sensor wires
Pre-installed
wires
White
White/Black
Yellow (for example)
Purple (for example)
Not Provided
Pre-installed wires
Safety reversing
sensor wires
7/16"
(11 mm)
Yellow
Purple
1
3
4
7/16"
(11 mm)
2
Yellow
(for example)
Purple
(for example)
To insert or remove the wires from
the terminal, push in the tab with a
screwdriver tip.
5
RED
WHITE
WHITE
GREY
D
RED
W
RE
WHITE
WHITE
GREY