background image

31

Using the Wall-Mounted Door Control

THE MULTI-FUNCTION DOOR CONTROL

Press the lighted push button to open or 
close the door. Press again to reverse the 
door during the closing cycle or to stop 
the door while it’s opening.

Light feature

Press the Light button to turn the opener light on or off. 
It will not control the opener lights when the door is in 
motion. If you turn it on and then activate the opener, the 
light will remain on for 4-1/2 minutes. Press again to turn 
it off sooner. The 4-1/2 minute interval can be changed to 
1-1/2, 2-1/2, or 3-1/2 minutes as follows: Press and hold 
the Lock button until the light blinks (about 10 seconds). 
A single blink indicates that the timer is reset to 1-1/2 
minutes. Repeat the procedure and the light will blink 
twice, resetting the timer to 2-1/2 minutes. Repeat again 
for a 3-1/2 minute interval, etc., up to a maximum of four 
blinks and 4-1/2 minutes.

Lock feature

Designed to prevent operation of the door from 
hand-held remote controls. However, the door will open 
and close from the Door Control, the Outdoor Keylock and 
the Keyless Entry Accessories.

 To activate, press and hold the Lock button for 2 seconds. 
The push button light will fl ash as long as the Lock feature 
is on.

To turn off, press and hold the Lock button again for 
2 seconds. The push button light will stop fl ashing. The 
Lock feature will also turn off whenever the “learn” button 
on the motor unit panel is activated.

Additional feature when used with the 
3-Button hand-held remote

To control the opener lights:

In addition to operating the door, you may 
program the remote to operate the lights.

1.   With the door closed, press and hold a small remote 

button that you want to control the light.

2.   Press and hold the Light button on the door control.

3.   While holding the Light button, press and hold the Lock 

button on the door control.

4.   After the opener lights fl ash, release all buttons.

Push 
Button

Lock 
Button

Light 
Button

To Open the Door Manually

DISCONNECT THE TROLLEY:

The door should be fully closed 
if possible. Pull down on the 
emergency release handle (so 
that the trolley release arm 
snaps into a vertical position) 
and lift the door manually. 
The 

lockout feature

 prevents 

the trolley from reconnecting 
automatically, and the door can 
be raised and lowered manually 
as often as necessary.

TO RE-CONNECT THE TROLLEY: 

Pull the emergency release 
handle toward the opener at 
an angle so that the trolley 
release arm is horizontal. The 
trolley will reconnect on the 
next UP or DOWN operation, 
either manually or by using 
the door control or remote.

To prevent possible SERIOUS INJURY or DEATH from 
a falling garage door:
•  If possible, use emergency release handle to 

disengage trolley ONLY when garage door is 
CLOSED. Weak or broken springs or unbalanced 
door could result in an open door falling rapidly and/
or unexpectedly.

•  NEVER use emergency release handle unless garage 

doorway is clear of persons and obstructions.

•  NEVER use handle to pull door open or closed. If 

rope knot becomes untied, you could fall.

Trolley

Trolley 
Release Arm 
(In Manual 
Disconnect 
Position)

Lockout Position 
(Manual Disconnect)

To Reconnect

Emergency 
Release Handle 
(Down and Back)

Trolley 
Release 
Arm

Trolley

Summary of Contents for Power Drive Security+ HD400DM

Page 1: ...aterials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks of the opener are req...

Page 2: ...r Control 31 To open the door manually 31 Care of your opener 32 Having a problem 33 Diagnostic chart 34 Programming 35 36 To add or reprogram a hand held remote control 35 To erase all codes 35 3 But...

Page 3: ...t Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or bindi...

Page 4: ...r and the bottom of the door must not exceed 1 4 6 mm Otherwise the safety reversal system may not work properly See Adjustment Step 3 Floor or door should be repaired SECTIONAL DOOR INSTALLATIONS Do...

Page 5: ...paired to eliminate the gap ONE PIECE DOOR WITHOUT TRACK FINISHED CEILING CLOSED POSITION Trolley Stop Bolt Cable Trolley Rail Header Bracket Door Bracket Straight Door Arm Garage Door Header Wall Cur...

Page 6: ...t is complete Multi Function Door Control Panel SECURITY 3 Button Remote Control 2 SECURITY Keyless Entry Idler Pulley Chain Spreader Door Bracket Header Bracket Curved Door Arm Section Straight Door...

Page 7: ...arriage Bolt 1 4 20x1 2 2 Lag Screw 5 16 9x1 5 8 2 Lag Screw 5 16 18x1 7 8 2 Self Threading Screw 1 4 14x5 8 2 Drywall Anchors 2 Clevis Pin 5 16 x1 1 4 1 Clevis Pin 5 16 x1 1 2 1 Clevis Pin 5 16 x1 1...

Page 8: ...wn and slide the tapered ends into the larger ones Tabs along the side will lock into place 3 Place the motor unit on packing material to protect the cover and rest the back end of the rail on top For...

Page 9: ...inside center should be pre greased If dry regrease to ensure proper operation Place the idler pulley into the window as shown Insert the idler bolt from the top through the rail and pulley Tighten w...

Page 10: ...the remaining master link 5 Thread the inner nut and lock washer onto the trolley threaded shaft Figure 3 6 Insert the trolley threaded shaft through the hole in the trolley Be sure the chain is not t...

Page 11: ...ced and lubricated garage door An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH 3 ALL repairs to cables spring assemblies and other hardware MUST be...

Page 12: ...or the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possi...

Page 13: ...ATION Extend the vertical centerline onto the ceiling as shown Center the bracket on the vertical mark no more than 6 15 cm from the wall Make sure the arrow is pointing away from the wall The bracket...

Page 14: ...way and place a 2x4 laid at on the top section beneath the rail If the top section or panel hits the trolley when you raise the door pull down on the trolley release arm to disconnect inner and outer...

Page 15: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to op...

Page 16: ...m of insulation from end of bell wire Connect bell wire to the quick connect terminals as follows white to white and white red to red Figure 5 NOTE When connecting multiple door controls to the opener...

Page 17: ...release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the oor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement Secure with an ov...

Page 18: ...Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be grounded Rei...

Page 19: ...re designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface suc...

Page 20: ...oor Attach brackets to wall with lag screws not provided If using extension brackets or wood blocks adjust right and left assemblies to the same distance out from the mounting surface Make sure all d...

Page 21: ...ollow the instructions below Cut the end of the safety reversing sensor wire making sure there is enough wire to reach the pre installed wires from the wall Figure 7 Separate the safety reversing sens...

Page 22: ...orrect wiring between sensors and opener A broken wire 2 If the sending eye indicator light glows steadily but the receiving eye indicator light doesn t Check alignment Check for an open wire to the r...

Page 23: ...g holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washers and nuts not provided Figure 2B Metal insulated or light weight fac...

Page 24: ...he door if required for your installation Refer to the dotted line optional placement drawing HARDWARE SHOWN ACTUAL SIZE Self Threading Screw 1 4 14x5 8 WOOD DOOR METAL DOOR Finished Ceiling HORIZONTA...

Page 25: ...e holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that line up an...

Page 26: ...Control push button The trolley will travel to the fully closed position Manually close the door and lift the door arm to the trolley The arm should touch the trolley just ahead of the door arm conne...

Page 27: ...force as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still...

Page 28: ...by turning the control clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the...

Page 29: ...nt of the opener ADJUSTMENT STEP 4 Test The Protector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button...

Page 30: ...also turn on when someone walks through the open garage door With a Multi Function Door Control this feature may be turned off as follows With the opener lights off press and hold the light button for...

Page 31: ...control the opener lights In addition to operating the door you may program the remote to operate the lights 1 With the door closed press and hold a small remote button that you want to control the l...

Page 32: ...mmediately notify doctor To reduce risk of re explosion or chemical burn Replace ONLY with 3V2032 coin batteries DO NOT recharge disassemble heat above 100 C 212 F or incinerate Care of Your Opener LI...

Page 33: ...ustments to force or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adju...

Page 34: ...or unit Momentarily short across red and white terminals with jumper wire If motor unit activates replace door control wires Symptom Sending indicator light glows steadily receiving indicator light is...

Page 35: ...s will be heard 1 Press and release the learn button on the motor unit The learn indicator light will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the hand held remote...

Page 36: ...ights will blink once when the PIN has been learned Test by pressing the new PIN then press Enter The door should move To set a temporary PIN You may authorize access by visitors or service people wit...

Page 37: ...t receiving and sending eyes with 3 feet 9 m 2 conductor bell wire 10 178B34 Straight door arm section 11 12B776 Hanging bracket 12 178B35 Curved door arm section 13 41A5266 1 Safety reversing sensor...

Page 38: ...cket bearing assembly RPM sensor KEY PART NO NO DESCRIPTION 11 41A5525 5 Cover 12 41A2818 Limit switch drive retainer 13 41D3452 Limit switch assembly 14 41A2822 1 Interrupter cup assembly 15 41C4398A...

Page 39: ...designed keyboard Also can add a temporary password for visitors or service persons This temporary password can be limited to a programmable number of hours or entries 3 Button Mini Remote Control wi...

Page 40: ...you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSA...

Reviews: