background image

5

201102-01

Decorative 

Screw

Fixture Top

TESTING AND ADJUSTMENTS

1.  Turn on the circuit breaker and light 

switch.

Note:

 Sensor has a 1 

1

/

2

 minute warm up period 

before it will detect motion. When first turned 

on wait 1 

1

/

2

 minutes.

2.  Set:

• ON-TIME switch to TEST

• SENSITIVITY to Mid (M) position

3.  Walk through the coverage area noting where 

you are when the lights turn on. In TEST mode, 

light will stay on for 5 seconds after motion has 

stopped and then turn off.

4.  Increase or decrease the sensitivity as needed. 

Too much sensitivity may cause false triggering 

due to heat sources in the coverage area (see 

Troubleshooting section).

5.  Set the amount of ON-TIME you want the 

light to stay on after motion is detected (1, 5, 

or 10 minutes). The timer will reset as long 

as there is motion present. Once motion has 

stopped,  the  timer  will  time-out  after  the 

selected amount of time.

Figure 5

9.1 m 

(30 ft.)

1.8 m 

(6 ft.)

  

Maximum

 

Maximum Range 

Coverage Angle*

 

(Side View) 

(Top View)

180°

TEST   1  5   10 MIN
        ON-TIME

LO - M - HI

SENSITIVITY

Summary of Contents for Secure Home SH-9191AU

Page 1: ...The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues Model Number 20...

Page 2: ... mounted 1 8 meters 6 feet above the ground Do not use dimmer switches or timers with this fixture The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile Traffic If you suspect tha...

Page 3: ...unting screws are paralleltotheground beforetighteningbracket to wall see Figure 2 5 Useapowerdrilltodrillintothewalltoprovide a suitable mounting for the screws Bracket mounting screws are not included Use 4mm dia 8G x 30mm wood screws Care should be taken to avoid drilling or screwing into concealed electrical wiring For solid brick walls screws and masonry plugs should be used 6 Attachmountingb...

Page 4: ...cable install fixture top using two decorative screws see Figure 5 WIRING WARNING Turn power off at circuit breaker or fuse Place tape over circuit breaker switch and verify power is off at the fixture Terminal Block From Fixture From AC Source Green Yellow Green Yellow Blue Blue or Black Brown Red or Brown Figure 3 Wall Mounting Bracket Mounting Screw Decorative Nut Figure 4 Connect the fixture w...

Page 5: ...or 5 seconds after motion has stopped and then turn off 4 Increase or decrease the sensitivity as needed Toomuchsensitivitymaycausefalsetriggering due to heat sources in the coverage area see Troubleshooting section 5 Set the amount of ON TIME you want the light to stay on after motion is detected 1 5 or 10 minutes The timer will reset as long as there is motion present Once motion has stopped the...

Page 6: ...ensor Capacity Up to 360 Watts 1 5A maximum tungsten incandescent Power Requirements 230 VAC 50 Hz Operating Modes TEST AUTO and MANUAL MODE ON Timer 1 5 10 minutes Test Timer 5 Seconds Manual Mode Timer Dusk to Dawn Ingress Protection IP23 MANUAL MODE AUTO TEST ON TIME Switch at 1 5 or 10 minutes MODE SWITCHING SUMMARY Flip light switch off for one second then back on If you get confused while sw...

Page 7: ...ating normally under these conditions 2 Set ON TIME switch to 1 5 or 10 minutes Light comes on for no apparent reason 1 Lightcontrolmaybesensingsmallanimalsorautomobile traffic 2 Sensitivity is set too high 1 Reduce sensitivity 2 Reduce sensitivity Light stays on continuously 1 The sensor may be picking up a heat source like an air vent dryer vent or brightly painted heat reflective surface 2 Ligh...

Page 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Reviews: