Rev J
Doc 01-20098
Page 18 of 44
K. BASIC GATE OPERATOR PROGRAMMING
Even if you plan to program the gate operator by telephone, you may want to enter some
immediate instructions during installation. The following list of instructions will help you set
basic controls so the gate will operate properly until you have time for full programming, either
directly or by telephone. For complete programming instructions, refer to the SL 1000, SW
2000, BG 3000 Programming Manual.
To access
programming mode: enter
✱ ✱ ✱
000000 (3 asterisks, 6 zeroes)
To program
a command:
a)
enter step number
b)
enter required data
c)
enter
#
(pound sign)
To exit
programming mode: enter 00
#
(2 zeroes, 1 pound sign)
Step
Purpose
# of
Digits
Default
Acceptable Input
01
Gate Type
(See Notes Below)
1
1
0 = Slide, 1 = Swing, 2 =
Barrier,
3 = Linear
02
Operator Type
1
0
0 = Single, 1 = Master, 2 =
Slave
03
Pair Type
1
0
0=Bipart, 1=Latch, 2=Not
Used, 3=Tandem
04
Not Used
-
-
-
05
Not Used
-
-
-
06
Anti-Tailgate Enable (ATG)
1
0
0 = Disabled, 1 = Enabled
07
Latch Delay Time
3
6
0 – 250 Seconds (.4 sec.
Increments)
08
Reclose Time (RT)
Up to 3
30
0 – 250 Seconds (0 =
Disabled)
09
Not Used
-
-
-
10
Not Used
-
-
-
11
Obstruction Sense
Backup
Closing
Up to 3
12
2 – 499 Inches
12
Obstruction Sense
Backup
Opening
Up to 3
12
2 – 499 Inches
13
Interrupt Bar Backup If Closing
Up to 3
12
2 – 499 Inches
14
Interrupt Bar Backup If Opening
Up to 3
12
2 – 499 Inches
15
Return to Factory Set Defaults
6
N/A
101010 (partial), 191919 (full)
NOTES:
1. If Gate Type is set to SLIDE, gate brakes whenever it stops.
2. If Gate Type is set to SWING, gate brakes only when it reaches the open or close limit.
1. If Gate Type is set to BARRIER or LINEAR, the gate never brakes.