Stopping the Engine
Gasoline
1. Turn off and unplug all electrical loads. Never start or stop
the generator with electrical devices plugged in or turned
on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the EZ Start dial counterclockwise to the STOP
position.
+
-
+
-
Important:
Always ensure that the EZ Start dial and fuel vent
on the fuel cap are in the “OFF” position when the generator is
not in use.
Propane
1. Turn off and unplug all electrical loads. Never start or stop
the generator with electrical devices plugged in or turned
on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Close the fuel valve on the propane cylinder.
4. Turn the EZ Start dial clockwise to the STOP position.
+
-
+
-
NOTICE
If the generator will not be used for a period of two (2) weeks
or longer, please see the
Storage section for proper engine
and fuel storage.
MAINTENANCE
Make certain that the generator is kept clean and stored
properly. Only operate the unit on a flat, level surface in a clean,
dry operating environment. DO NOT expose the unit to extreme
conditions, excessive dust, dirt, moisture or corrosive vapors.
NOTICE
When the Maintenance Indicator light is yellow, service is
required per the Maintenance Schedule Section. To reset
the Maintenance Indicator Light, hold down the AC Overload
Reset Button for 3 seconds. (See Power Panel section under
Controls and Features.)
WARNING
Never operate a damaged or defective generator.
WARNING
Improper maintenance will void your warranty.
NOTICE
Maintenance, replacement, or repair of emission control
devices and systems may be performed by any non-road
engine repair establishment or individual.
The owner/operator is responsible for all periodic maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
For service or parts assistance, contact our
Technical Support Team at 1-877-338-0999.
Cleaning the Generator
CAUTION
DO NOT spray engine with water.
Water can enter the generator through the cooling slots and
damage the generator windings. It can also contaminate the
fuel system.
1. Use a damp cloth to clean exterior surfaces of the
generator.
2. Use a soft bristle brush to remove dirt and oil.
3. Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
4. Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.