100402 - 2000W DUAL FUEL INVERTER GENERATOR
MAINTENANCE
25
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the
spark arrestor.
2. Remove the 4 screws holding the cover plate on the
muffler side of the generator.
3. Remove the clamp(C) and cap(B) which retain the spark
arrestor(A) to the muffler.
A
b
C
4. Remove the spark arrestor screen.
5. Carefully remove the carbon deposits from the spark
arrestor screen with a wire brush.
6. Replace the spark arrestor if it is damaged.
7. Position the spark arrestor on the muffler and attach by
reversing the steps from above.
CAUTION
Failure to clean the spark arrestor will result in degraded
engine performance.
NOTICE
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required.
When ordered, spark arrestors are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest-covered
land, brush-covered land, or grass-covered land unless the
engine is equipped with a spark arrestor.
DELETE "NATIONAL FOREST" NOTICE IF CANADA ONLY ITEM
Replacing Fuel Light batteries
1. Use a small screwdriver to disassemble the upper cover.
NOTICE
There is a notch on both sides to allow access with a
screwdriver.
2. Move the round copper cover plate and remove the battery
cells.
3. Keep the small spring attached to the copper pillar and
place the compressed spring back into the bottom of the
assembly.
NOTICE
The compressed spring will have the small end facing
outward.
4. Place new battery cells (2 × LR1130) back into the
assembly with negative (−) pole facing upwards and
positive (+) facing towards the compressed spring. Move
the round copper cover plate to cover and touch the button
cell.