100455 - 2000W PORTABLE INVERTER GENERATOR
STORAGE
21
If the gasoline tank and carburetor were properly emptied of all
gasoline prior to the generator being stored, follow the below
steps when removing from storage.
1. Be sure the engine switch is in the “OFF” position.
2. Add gasoline to the generator according to
Add Fuel:
Gasoline
.
3. Turn the fuel valve to the “ON” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If no
gasoline leaks are found, turn the fuel valve to the “OFF”
position.
5. Check engine oil level and add clean, fresh oil if needed.
See
Oil Specifications
for proper oil type.
6. Check and clear air filter of any obstructions such as bugs
or cobwebs. If necessary, clean air filter according to
Cleaning the Air Filter
.
7. Start the generator according to
Starting the Engine
.
!
DANGER
Generator exhaust contains odorless and colorless carbon
monoxide gas.
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should
be followed:
–
When storing the generator make sure the engine switch
and fuel valve are set to the “OFF” position.