background image

73534i

2000 Max Watts / 1600 Rated Watts

PORTABLE INVERTER GENERATOR

TABLE Of CONTENTS

Introduction

1

Introduction

1

Portable Power Generator

1

Accessories

1

This Booklet

1

Manual Conventions

2

Safety Rules

3

Controls and Features

5

Generator

5

Parts Included

5

Power Panel

6

Assembly

7

Remove the Generator from the Shipping Carton 7
Add Engine Oil

7

Add Fuel

8

Grounding

8

Operation

9

Generator Location

9

Grounding

9

Starting the Engine

9

Economy Control Switch

10

Connecting Electrical Loads

10

12V DC Outlet

11

12V DC Outlet – Battery Charging

11

Stopping the Engine

11

Do Not Overload Generator

12

Capacity

12

Power Management

12

Overload Operation

12

Parallel Operation

12

Maintenance and Storage

13

Engine Maintenance

13

Oil

13

Spark Plugs

13

Air Filter

14

Cleaning

14

Spark Arrester Cleaning

14

Adjustments

14

Maintenance Schedule

15

Generator Maintenance

15

Storage

15

Generator Storage

15

Specifications

16

Engine Specifications

16

Generator Specifications

16

Fuel

16

Oil

16

Spark Plugs

16

Maintenance Valve Clearance

16

An Important Message About Temperature

16

IC Warning

16

Parts Diagram

17

Parts List

18

Engine Parts Diagram

19

Engine Parts List

20

Wiring Diagram

21

Troubleshooting

22

Warranty

23

Warranty Qualifications

23

Repair/Replacement Warranty

23

Do Not Return The Unit To
The Place Of Purchase

23

Warranty Exclusions

23

Normal Wear

23

Installation, Use and Maintenance

23

Other Exclusions

23

Limits of Implied Warranty
And Consequential Damage

23

Contact Information

23

Address

23

Customer Service

23

Technical Service

23

Summary of Contents for 73534i

Page 1: ...SA 1 877 338 0999 www championpowerequipment com PORTABLE INVERTER GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 73534i 20131219 2000 Max Watts 1600 Rated Watts OWNER S MANUAL OPERATING INSTRUCTIONS 73534i MODEL NUMBER ...

Page 2: ...re Team Toll Free at 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F When your product is needed your product may be operated at temperatures ranging from 15 C 5 F to 50 C 122 F for short periods If the product is exposed to temperatures outside this range during stor...

Page 3: ...n 12 Maintenance and Storage 13 Engine Maintenance 13 Oil 13 Spark Plugs 13 Air Filter 14 Cleaning 14 Spark Arrester Cleaning 14 Adjustments 14 Maintenance Schedule 15 Generator Maintenance 15 Storage 15 Generator Storage 15 Specifications 16 Engine Specifications 16 Generator Specifications 16 Fuel 16 Oil 16 Spark Plugs 16 Maintenance Valve Clearance 16 An Important Message About Temperature 16 I...

Page 4: ...e this information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers and power cables please visit our web site at www championpowerequipment com This Booklet Every effort has been made to ensure the accuracy and ...

Page 5: ...ly hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage CAUTION DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury DANGER WARNING indicates a potentially hazardous s...

Page 6: ...as metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can result in fire or electrical shock When servicing the generator Disconnect the spark plug wire and place it where it cannot contact the plug DO NOT check for spark with the plug removed Use only appr...

Page 7: ...cal equipment in the off position and then turn them on for operation Turn electrical equipment off before stopping the generator DO NOT tamper with the governed speed DO NOT modify the generator in any way CAUTION Fuel and fuel vapours are highly flammable and extremely explosive Fire or explosion can cause severe burns or death Unintentional startup can result in entanglement traumatic amputatio...

Page 8: ...to the On position to supply air to the tank 3 Fuel Cap Remove to add fuel 4 Recoil Starter Used to start the engine 5 Spark Plug Access Cap 6 Maintenance Cover Oil filler air filter and carburetor access 7 Muffler Inverter Controls and Features Parts Included Your 73534i Gasoline Powered Generator ships with the following parts Oil funnel 1 Spark plug socket 1 Automotive style USB adapter 2 1A an...

Page 9: ...is required for parallel operation Controls and Features 2 1 8 3 4 5 12 9 6 7 10 11 13 14 8 Parallel Operation Control 9 Parallel Operation Outlets 10 120 V Duplex Use this duplex to operate 120 Volt AC single phase 60 Hz loads 11 Circuit Breaker Flip Protects the generator against electrical overload 12 Ground Terminal Consult an electrician for local grounding regulations 13 Circuit Breaker Push...

Page 10: ... cover 4 Add 0 4 L 0 4 qt of oil and replace oil fill cap dipstick DO NOT OVERFILL 5 Check engine oil level daily and add as needed 3 Remove oil fill cap dipstick to add oil The recommended oil type is 10W 30 automotive oil NOTE Add Engine Oil DO NOT attempt to crank or start the engine before it has been properly filled with the recommended type and amount of oil Damage to the generator as a resu...

Page 11: ... fuel Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 6 4 mm in below the top of the tank to allow for fuel expansion DO NOT pump gas directly into the generator at the gas station Use an approved container to transfer the fuel to the generator DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine is running or h...

Page 12: ...the bed of a truck regular flat or otherwise under staircases stairwells next to walls or buildings or in any other location that will not allow for adequate cooling of the generator and or the muffler DO NOT contain generators during operation Allow generators to properly cool before transport or storage Place the generator in a well ventilated area DO NOT place the generator near vents or intake...

Page 13: ...c generator during an outage please notify your electric utility company immediately and remember to plug your appliances directly into the generator Do not plug the generator into any electric outlet in your home Doing so could create a connection to the utility company power lines You are responsible for ensuring that your generator s electricity does not feed back into the electric utility powe...

Page 14: ...C output is unregulated and can damage some products Confirm your accessory input voltage range is at least 12 21V DC When using the DC outlet turn the Economy mode switch to the OFF position 12V DC Outlet Battery Charging 1 Before connecting the battery charging cable to a battery that is installed in a vehicle disconnect the vehicle battery ground cable from the negative battery terminal 2 Plug ...

Page 15: ... turn on when the rated load is exceeded When the maximum load is reached the LED will blink and cut power to the receptacles To recover the power shut down the engine wait until the light turns off and restart the generator Parallel Operation Two Champion model 73534i generators can be operated in parallel to increase the total available electrical power to 3000 watts A Champion model 73500i para...

Page 16: ...nt facility Spark Plugs 1 Remove the maintenance cover 2 Remove the spark plug cable from the spark plug 3 Use the spark plug tool that shipped with your generator to remove the plug Remove the spark plug access cap and insert the spark plug tool through this hole 4 Remove the spark plug 5 Inspect the electrode on the plug It must be clean and not worn to produce the spark required for ignition 6 ...

Page 17: ...n a clean cloth 5 Saturate in clean engine oil 6 Squeeze in a clean absorbent cloth to remove all excess oil 7 Place the filter in the assembly 8 Reattach the air filter cover 9 Reinstall the maintenance cover and tighten the cover screw securely Use a damp cloth to clean exterior surfaces of the engine Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and ...

Page 18: ...surfaces of the generator Use a soft bristle brush to remove dirt and oil Use an air compressor 25 PSI to clear dirt and debris from the generator Inspect all air vents and cooling slots to ensure that they are clean and unobstructed Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule Service your generator more frequently when operating in adverse con...

Page 19: ...0cc Type 4 Stroke OHV Start Type Recoil Spark Plugs OEM spark plug NHSP E6RTC Replacement spark plug NGK BPR6HS or equivalent Make certain the spark plug gap is 0 6 0 7 mm or 0 024 0 028 in IC Warning This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any...

Page 20: ...2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 2 17 8 28 37 44 1 45 46 5 2 32 47 48 49 50 2 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 64 65 64 65 64 65 1 1 45 71 72 73 74 75 32 76 77 ...

Page 21: ...6 81 130200 00 Pull Choke Assembly 1 37 1 818 0412 3 Screw M4 12 3 38 81 070001 00 Fuel Knob 1 Part Number Description Qty 39 5 1010 001 1 Switch 2 40 81 211100 00 2 Operation Panel 1 41 81 126000 00 Ignition Assy 1 42 81 210200 01 Toroid Coil Comp 1 43 81 211001 00 Control Box Operation Panel 1 44 81 061200 00 Guide Rope 1 45 2 02 015 Nut M6 4 46 81 200101 01 2 Front Cover Black 1 47 81 200200 00...

Page 22: ...7 18 19 20 1 21 22 23 24 25 13 26 27 28 29 30 31 33 34 35 32 1 37 38 39 40 41 42 43 44 45 48 49 1 50 51 52 36 53 54 55 56 57 58 59 60 61 47 62 63 64 19 65 46 47 66 67 68 69 70 72 58 73 74 13 75 76 77 78 79 80 81 82 84 85 83 86 87 15 16 71 3 13 88 89 90 70 91 92 93 95 96 97 99 101 102 103 94 98 100 104 105 106 ...

Page 23: ... 52 81 101100 00 Muffler Assembly 1 53 81 100001 00 Gasket EX 1 54 81 081100 00 Muff Protector Side 1 Part Number Description Qty 55 81 081003 00 Fastening Insert 1 56 81 081001 00 Muff Protector Seal 1 57 81 080003 00 Air Duct 1 58 1 6177 1 06 3 Flange Nut M6 6 59 81 020001 00 Breather Tube 1 60 81 021000 00 Cylinder Head Cover 1 61 81 020002 00 Gasket Cylinder Head Cover 1 62 81 080200 00 Air Sh...

Page 24: ... L W G B Y R YELLOW BLACK BLUE GREEN RED WHITE Br WHITE BLUE GREEN YELLOW WHITE GREEN BROWN BLACK WHITE B W W L G Y W G GENERATOR ENGINE IGNITION COIL G 5 20R AC COIL SUB COIL C W B W O L Y A G Y O B W C W O Y L C B G Y L R R R Y Y R W B L TCI UNIT R R B G Y G Y G Y C CARNATION A AMETHYST O ORANGE OUTPUT PANEL CONTROL PANEL PARALLEL POWER UNIT R B G Y R B G G PARALLEL OPERATION CONTROL B Y R G CIR...

Page 25: ...lug Generator shuts down during operation Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connecte...

Page 26: ... labour if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical component Installation Use and Maintenance Cont d Normal maintenance such as spark plugs air filters adjustments fuel system cleaning and obstruction due to buildup is not covered by this warr...

Page 27: ...bject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRANTY RESPONSIBILITIES As the small off road engine owner you are responsible for the performance of the required maintenance listed in your Owner s Manual CPE recommends that you retain all your receip...

Page 28: ...all be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according ...

Page 29: ...stalled along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to sell and service that CPE product during his normal business hours Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine...

Reviews: