5) Install the Engine and Hoses Cont’d.
6) Install the Engine and Hoses Cont’d.
4 . Connect one end of the clear oil hose to the hydraulic
oil tank just beneath the engine and the other end to
the pump inlet on the bottom of the pump . (C)
The swivel nut end of the high pressure hose
connects to the pump outlet .
NOTE
C
B
A
Add Hydraulic Oil
1 . Make sure the log splitter is on a flat, level surface .
2 . Remove the oil plug from the oil tank . (A)
3 . Add 5 gal . (18 .9 L) of hydraulic oil - 10W AW32, ASLE
H-150, or ISO 32 are all acceptable types of fluid .
4 . Check the hydraulic oil level using the oil sight
glass . Oil level should visibly fill the glass sight . (B)
5 . Replace and tighten the oil plug and orient the vent
hole away from the operator zone .
High Pressure Hose
– This is the only hose with steel connectors crimped on
both ends .
– One end connects to the control valve (sealed with
teflon tape) .
– Other end connects to the top of the pump (sealed by
O-Ring) .
– Because of the male/female ends, this hose only fits
the correct way .
Suction Hose
– This is the clear hose that connects the hydraulic tank
to the pump inlet .
– Both ends of the hose are secured with hose clamps .
Oil Return Hose
– This hose returns the oil exiting the cylinder to the tank
– It has no connectors crimped onto it .
– The hose ends push over barbed fittings on the control
valve and the oil filter .
– Both ends are secured with hose clamps .
– Notice how the hose is placed through the retainer
ring on the beam . This holds the hose close to the
frame so it does not flop out beyond the wheels (and
catch on things while towing) .
A
B
5 . Install the hose retaining ring to the side of the
splitting beam . (D)
6 . Place the oil return hose through the retaining ring
and connect it to the barb fitting on the control valve .
Connect the other end of the hose to the barb fitting
on the oil filter . (E)
d
E
The pump outlet connection does NOT require teflon
tape . The o-ring seals against the face of the fittings on
the pump and hose . Tighten to approximately 12 ft-lb .
Over-tightening can damage the pump .
NOTE