ASSEMBLY
Your generator requires some assembly. This unit ships from
our factory without oil. It must be properly serviced with fuel
and oil before operation.
If you have any questions regarding the assembly of your
generator, call our Technical Support Team at 1-877-338-0999.
Please have your serial number and model number available.
Unpacking
1. Set the shipping carton on a solid, flat surface.
2. Remove everything from the carton except the generator.
3. Using the carrying handles of the unit, carefully remove
the generator from the box (two people lifting is
recommended).
Connect the Battery
1. Using a screwdriver, remove the two maintenance cover
screws from the battery maintenance cover.
2. Once the screws have been removed, the rubber pull-tab
on the cover can be pulled out to help loosen and dislodge
the maintenance cover.
3. Remove the battery maintenance cover.
4. Cut zip tie that is binding the battery cables together.
5. Using a screwdriver, unscrew the battery bolt in the red,
positive (+) battery terminal.
6. Connect the red, positive (+) wire lead to the positive (+)
terminal on the battery using the bolt.
7. Pull rubber sheath over battery cable connection and
battery terminal.
8. Repeat steps 5-7 for the black, negative (–) battery wire
lead and black, negative (–) battery terminal.
"
NOTICE
If the battery cables are not visible once the battery
maintenance cover has been removed, please note that
cables may be tucked up above the battery, not in plain
view.
Add Engine Oil
!
CAUTION
DO NOT attempt to crank or start the engine before it has
been properly filled with the recommended type and amount
of oil. Damage to the generator as a result of failure to
follow these instructions will void your warranty.
"
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing
that requires no additional lubrication for the life of the bearing.
"
NOTICE
The recommended oil type is
10W-30 automotive oil
.
-20
0
20
40
60
Ambient temperature / Temperatura ambiente / Température ambiante
Recommended Oil Type / Tipo de aceite recomendado / Type d’huile recommandé
80
100
120
-28.9
°F
°C
-17.8 -6.7 4.4
15.6 26.7 37.8
48.9
10W-30
5W-30 Synthetic / Sintético / Synthétique
10W-40
5W-30
1. Place the generator on a flat, level surface.
2. Loosen the cover screws and remove the maintenance
cover.
3. Remove oil fill cap/dipstick to add oil.
4. Using a funnel, add up to 0.6 qt. (0.6 L) of oil (not included)
and replace oil fill cap/dipstick. DO NOT OVERFILL.
5. Check engine oil level daily and add as needed.