100477 - 3150W REMOTE START INVERTER GENERATOR
OPERATION
18
Neutral Bonded to Frame*
–
Neutral circuit
IS
electrically connected to the frame/ground
of the generator.
–
The generator system ground connects lower frame
cross-member below the alternator. The system ground is
connected to the AC neutral wire.
* See your model's control panel for specified type of grounding.
Surge Protection
Electronic devices, including computers and many
programmable appliances use components that are designed
to operate within a narrow voltage range and may be affected
by momentary voltage fluctuations. While there is no way to
prevent voltage fluctuations, you can take steps to protect
sensitive electronic equipment.
–
Install UL1449, CSA-listed, plug-in surge suppressors on the
outlets feeding your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles.
They’re designed to protect against virtually all short-
duration voltage fluctuations.
Wireless Set Button
The wireless set button is a feature that lets the user sync
remote controls to the generator. One can set up to two remote
controls or reset a remote control with the generator. To reset a
remote control or sync two remote controls follow these steps:
1. Turn the ignition switch to the “ON” position.
2. Turn the battery switch to the “ON” position.
3. Push and hold the wireless set button for approximately
three seconds. The red light will turn on.
4. Push and release the STOP button on the remote. The red
light blinks once to erase the remote program.
5. Push and release the START button. The red light blinks
once to program the remote.
6. Push and hold the programming button approximately
three seconds until the red light turns off.
7. Test start and stop features.
"
NOTICE
Only two remote controls can be synced with one generator
at a time.
"
NOTICE
Changing a remote control battery may not require the user
to reset the remote control.
Starting the Engine
1. Make certain the generator is on a flat, level surface.
2. Turn the gasoline fuel valve to the “ON” position (A).
Wireless Remote Start
Wireless remote starting is only possible within 80 feet of the
generator.
DO NOT attempt to adjust the choke. The remote system will
automatically close and open the choke.
1. Push the battery switch to the “ON” position (B).
2. Push the ignition switch to the “ON” position (D).
3. Press and release the “START” button on the remote
control. DO NOT hold the button down, only press the
button once. The engine will attempt to start six times.
Electric Start
1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices
plugged in or turned on.
2. Push the battery switch to the “ON” position (B).
3. Push the choke button to the “CHOKE” position (C).
4. Push the ignition switch to the “ON” position (D).
5. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails
to start within five seconds, release the switch and wait
at least ten seconds before attempting to start the engine
again.
6. Do not over-choke. As soon as engine starts, push the
choke to the “RUN” position.