100477 - 3150W REMOTE START INVERTER GENERATOR
OPERATION
19
!
CAUTION
If the ignition switch is held down in the “START” position
longer than 5 seconds it could damage the starter.
Manual Start
1. Disconnect all electrical loads from the generator. Never
start or stop the generator manually with electrical devices
plugged in or turned on.
2. Push the battery switch to the “ON” position (B).
3. Push the choke button to the “CHOKE” position (C).
4. Push the ignition switch to the “ON” position (D).
5. Pull the starter cord slowly until resistance is felt and then
pull rapidly
6. Do not over-choke. As soon as engine starts, push the
choke to the “RUN” position.
A
B
C
D
"
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil
starter. After first pull, push the choke to the “RUN” position
for up to the next 3 pulls of the recoil starter. Too much
choke leads to spark plug fouling/engine flooding due to the
lack of incoming air. This will cause the engine not to start.
"
NOTICE
If the engine starts but does not run make certain that the
generator is on a flat, level surface. The engine is equipped
with a low oil sensor that will prevent the engine from
running when the oil level falls below a critical threshold.
Manual Choke Start
If the battery is dead or not able to produce enough current to
power the push button choke, the choke itself can be operated
manually to help start the engine. To manually choke and start
the inverter, follow these steps:
1. Loosen the screws and remove the maintenance cover.