100477 - 3150W REMOTE START INVERTER GENERATOR
MAINTENANCE
24
SPARK PLUG GAP
LA ABERTURA DE LA BUJÍA
L’ÉCARTEMENT DE LA BOUGIE
6. Refer to the spark plug types in
Specifications
when
replacing the plug.
7. Firmly re-install the plug.
8. Attach the spark plug cable to the spark plug.
9. Reinstall the spark plug access cap (if applicable) and
maintenance cover.
Cleaning the Air Filter
1. Remove the maintenance cover.
2. Locate the air filter plastic cover.
3. Unsnap the locking hinge on the cover.
4. Remove the old filter.
5. Place the new filter in the assembly.
6. Re-snap the hinge on the air filter cover.
7. Reinstall the maintenance cover and tighten the cover
screw securely.
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the
spark arrestor.
2. Remove the two or three screws (varies by model) holding
the cover plate which retains the spark arrestor to the
muffler.
3. Remove the spark arrestor screen.
4. Carefully remove the carbon deposits from the spark
arrestor screen with a wire brush.
Type 1
Type 2
* See your model’s parts list for specified type of spark arrestor.
5. Replace the spark arrestor if it is damaged.
6. Position the spark arrestor on the muffler and attach with
the screws removed in step 2.
!
CAUTION
Failure to clean the spark arrestor will result in degraded
engine performance.
"
NOTICE
Federal and local laws and administrative requirements
indicate when and where spark arrestors are required.
When ordered, spark arrestors are required for operation
of this generator in National Forest lands. In California,
this generator must not be used on any forest-covered
land, brush-covered land, or grass-covered land unless the
engine is equipped with a spark arrestor.
Adjusting the Governor
!
WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with
the governor can damage your generator and your
electrical devices and will void your warranty. Contact our
Technical Support Team at 1-877-338-0999 for all other
service and/or adjustment needs.
Generator Battery
Your generator is equipped with an automatic battery charging
circuit that charges the battery while the engine is running.
The battery will maintain a proper charge if the unit is used on
a regular basis (about once every two weeks). If it is used less
frequently, the battery should be connected to a trickle charger
or battery maintainer (not included) to keep the battery properly
charged.
Maximum charging rate should not exceed 1.5 amps. Follow
the instructions included with the battery charger. The battery
should be fully charged at least once per month. If the battery
is not able to start the engine, it can be started by manually
pulling the engine recoil cord. If the battery voltage is extremely
low, the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a
standard automotive style battery charger for re-charging
before it can be used.
Disconnect the Battery
1. Remove the protective cover from the black (–) battery
lead.
2. Disconnect the black (–) lead from the black (–) terminal on
the battery and store the cap screw and nut.
3. Repeat steps 1-2 for the red (+) battery lead.