100520 - 8750W PORTABLE INVERTER GENERATOR
STORAGE
26
Maintenance Schedule
Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate
the nearest CPE certified service dealer for your generator or
engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
Check oil level
Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
Change oil
EVERY 50 HOURS OR ANNUALLY
Clean air filter
Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
Change oil
Clean/adjust spark plug
Clean spark arrestor
Clean fuel valve filter*
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
DANGER
Gasoline vapors are highly flammable and extremely explosive.
Fire or explosion can cause severe burns or death. Only
fill or drain fuel outdoors in a well-ventilated area. DO NOT
pump gasoline directly into the generator. Use an approved
container to transfer the fuel to the generator. Never use a
gasoline container, gasoline tank, or any other fuel item that
is damaged or appears damaged. DO NOT overfill the gasoline
tank. Always keep fuel away from sparks, open flames, pilot
lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.
Short Term Storage (up to 30 days)
Gasoline may gum up and clog the carburetor if the generator is
not run or carburetor drained within 4 weeks.
1. Be sure all appliances are disconnected from the generator.
2. Start the generator as instructed in
Starting the Engine
section.
3. Turn the fuel valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped the
engine. This usually takes a few minutes.
5. Move the engine switch to the “OFF” position.
Mid Term Storage (30 days – 1 year)
Gasoline in the tank has a maximum shelf life of up to 1 year with
the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the “ON” position.
4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system.
5.
Option 1: Drain Gasoline from Carburetor
5a. Turn engine switch to the “OFF” position and allow
generator to cool completely before continuing.
5b. Turn the fuel valve to the “OFF”.
5c. Use the drain bolt on the carburetor to empty any
excess gasoline from the carburetor into an appropriate
container. Use a funnel (and appropriate hose if
necessary) under the carburetor drain bolt to avoid
spillage.