background image

100594 - 1600 PORTABLE POWER STATION

CONTROLS AND FEATURES

13

CONTROLS AND FEATURES

Read this operator’s manual before operating your Power Station. Familiarize yourself with the location and function of the controls and 
features. Save this manual for future reference.

Power Station

1. 

Carrying Handle(s) 

 

Used to lift or carry the unit.

2. 

Overload Reset/THD Shield Button 

– Press 1x to  

re-energize both AC and DC outlets after overload fault.  
Press 5x in three seconds to turn THD Shield ON/OFF.

3. 

Control Panel 

 

See 

Control Panel

 section.

4. 

LED Light

 – Used to illuminate the work area in front of the 

Power Station.

5. 

LED Light Button 

– Used to turn LED light ON/OFF.

6. 

AC Fast Charge - 120V AC, 60Hz, 4.5A MAX 

– Used to 

charge the Power Station from a regular wall outlet. Uses 
included cord.

7. 

DC Fast Charge - MPPT Solar - 10V-28V DC, 25A MAX 
(APP Anderson Power Pole DC)

 – Used to charge the Power 

Station from solar panel(s). Uses included Easy Connect 
DC Solar Charge Harness from 1x APP (plug into the Power 
Station) to 3x MC4 (connect to the solar panels) connectors - 
Solar panels not included.

8. 

External Battery Port

 – Used to increase the Power 

Station run time by adding additional external batteries 
(Model 201107 - Expansion Battery Pack not included, sold 
separately).

9. 

Charging Module Slots 

– Used to remove or connect the 

charging module from the unit. When necessary, gently 
pry and remove the charger module out with a flathead 
screwdriver.

10. 

Charging Terminals 

– Used to connect the charging modules 

when positioned in the charger module slots.

1

1

4

3

2

5

6

9

10

7

8

Summary of Contents for 100594

Page 1: ...mpionpowerequipment com READ AND SAVE THIS MANUAL This manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in se...

Page 2: ...nnect DC Solar Charge Harness 20 Recommended Solar Panels 21 Using APP Port 21 Operation 22 Using the Power Station 22 Standby Mode 22 LED Light 22 Connecting Electrical Loads 23 Resetting the Output...

Page 3: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Page 4: ...ratings on the Power Station and accessory products you intend to use CAUTION In outdoor conditions this device is intended for temporary outdoor use only Reasonable care should always be exercised wh...

Page 5: ...wer tools Connect only to properly grounded outlets To reduce risk of damage to the electric plug and cord pull the plug rather than the cord when disconnecting the Power Station Never use the cord fo...

Page 6: ...rain snow damp or wet locations Do not overcharge the Power Station internal battery Always connect to properly grounded outlets Never use Power Station or charger in the presence of explosive atmosp...

Page 7: ...es and counties it may be illegal to dispose of these batteries in standard household waste To dispose the battery safely apply tape over any exposed connectors to prevent accidental shorting of the p...

Page 8: ...TS WATTS AU D MARRAGE DE CR TE 120V 60Hz 1600W 100594 XXXX 1600 3200 4500 1 USB Type C PD3 0 60W 1 USB Type C PD3 0 60W 2 USB A 2 USB A 1 USB Type C QC3 0 1 USB Type C QC3 0 5V 2 1A 1 Anderson Powerpo...

Page 9: ...electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Shield eyes Explosive gases...

Page 10: ...roduct uses lithium ion Li ion batteries Local state or federal laws prohibit disposal of Li ion batteries in ordinary trash In the United States and Canada a large network of over 30 000 battery drop...

Page 11: ...for 3 seconds to power ON OFF Press for 1 second to power AC outlets ON OFF Circuit Breaker Reset Push Parallel Connection s AC Output DC Output 12V Direct Current Ground Terminal Neutral Floating Ne...

Page 12: ...eld button 5x within three seconds 4 Plug in desired devices NOTICE To protect sensitive electronics as the Power Station s battery level drops below 30 THD Shield is designed to shut off AC power out...

Page 13: ...e 120V AC 60Hz 4 5A MAX Used to charge the Power Station from a regular wall outlet Uses included cord 7 DC Fast Charge MPPT Solar 10V 28V DC 25A MAX APP Anderson Power Pole DC Used to charge the Powe...

Page 14: ...ole May be used to supply electrical power for operation of 12 Volt DC 20 Amp electrical loads B z 12V DC 10A Regulated Automotive May be used to supply electrical power for operation of 12 Volt DC 10...

Page 15: ...11 11 120V The 120V AC outlets are powered on and ready for use when steady blue Steady red if overloaded or fault has occurred in 120V AC inverter or outlets see Resetting the Output section 12 THD...

Page 16: ...to charge to full 0 watts out battery is at 10 H 1 2 W Charging Watts Example 384 Watts charging in 0 watts out battery is at 10 1 2 W W Discharging Hours Example 2 0 Hours to empty 0 watts in batter...

Page 17: ...HD steady red AC output shut off due to THD above 5 1 2 W W THD Shield Disabled THD 5 Example THD Shield disabled icon will be steady blue when THD is below 5 AC output will not shut off until battery...

Page 18: ...experiencing a fault See figure to the right 12V DC USB Port Fault Example Fault in 12V DC port location 1 APP and USB port location 3 USB PD Check devices cables or lower load Press overload reset bu...

Page 19: ...pt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause und...

Page 20: ...itive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Charging From Wall NOTICE The Power Statio...

Page 21: ...Solar Panel 200 Watt 12 Volt 200 MC4 Bluetti SP120 120 MC4 Bluetti SP200 200 MC4 ECOFLOW EFSOLAR 160W 160 MC4 Any solar panel rated between 10 28V with MC4 or APP connectors can be used The Power Stat...

Page 22: ...n a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section 4 To turn THD Shield off press THD Shield button 5x within three seconds 5 Plug in desired...

Page 23: ...C outlets 1 Unplug all devices 2 For AC output errors only Check to see if Power Station s circuit breaker is tripped If tripped push in to reset 3 Press the reset button 4 If overload is due to high...

Page 24: ...Management Use the following formula to convert voltage and amperage to watts Volts Amps Watts To prolong the life of your Power Station and attached devices follow these steps to add electrical load...

Page 25: ...ly with water No user serviceable parts for maintenance required Water can enter the Power Station through the cooling slots and damage the Power Station electronics 1 Use a damp cloth to clean exteri...

Page 26: ...5 3 cm Width 10 8 in 27 5 cm Height 12 3 in 31 3 cm Battery Specifications Chemistry Lithium ion NMC Pack Rated Output Voltage 46 8 Pack Max Output Voltage 55 Pack Capacity 1638 Wh Single Cell Equival...

Page 27: ...perature warning light Turn the unit off place it in the shade or a cooler area and let it cool down Check that the unit is not overloaded Unit is too cold Check display for flashing red Low Temperatu...

Page 28: ...you reach 440W of charging power Unit is nearing 100 battery level and is slowing down to a safer charging rate The charging power and rate is reduced as the battery level gets closer to 100 to safely...

Page 29: ...ot apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abused loaded beyond the product s limits modified installed improperly or connected inco...