background image

100594 - 1600 PORTABLE POWER STATION

IMPORTANT SAFETY INSTRUCTIONS

5

Lithium-ion Battery Safety

 

DANGER

Electrolyte inside the battery is harmful to skin and eyes. 
Electrolyte may pose an increased risk of harm if not handled 
properly. 

Under abusive conditions, liquid may be ejected from the 
battery; avoid contact. Liquid ejected from the battery may 
cause irritation or burns. If contact accidentally occurs, flush 
with water. If the battery leaks and electrolyte gets in your 
eyes, do not rub them, immediately flood eye with running cold 
water for at least 10 minutes and seek medical help. If left 
untreated, electrolyte can cause permanent eye injury. Keep 
away from children.

 

DANGER

This Power Station generates the same potential lethal AC 
electrical voltage as a standard building wall outlet.

Always treat the Power Station as you would a normal AC 
outlet on a standard building wall.

 

WARNING

When using the Power Station:

 

Always use in a dry well ventilated area while in use and 
do not obstruct fan openings on unit. Inadequate ventilation 
may cause execessive heat and damage the unit.

 

Always keep the unit clean and dry and inspect for dirt, 
dust, or moisture prior to every use.

 

Power cord plugs must always match the outlet. Never 
modify the plug in any way. Do not use any adapter plugs 
with earthed (grounded) power tools.

 

Connect only to properly grounded outlets.

 

To reduce risk of damage to the electric plug and cord, 
pull the plug rather than the cord when disconnecting the 
Power Station. Never use the cord for carrying, pulling or 
unplugging the tool.

 

Do not use this Power Station if the power cord or the 
battery cables are damaged in any way.

 

Always use a suitable extension cord to reduce the risk of 
electric shock.

 

Always keep the cord away from heat, oil, sharp edges or 
moving parts.

 

Always position cords carefully to avoid hazardous 
conditions. Tripping or snagging on cords can cause 
injury or cause product damage. Never allow cords to run 
through puddles or across wet ground.

 

Use of an accessory attachment not recommended or sold 
by the Power Station manufacturer may result in a risk of 
fire, electric shock, or injury to persons.

 

To reduce the risk of electric shock always unplug the 
cord from outlet when not in use and before servicing or 
cleaning.

 

Do not insert foreign objects into outputs or ventilation 
holes.

 

WARNING

 

Do not overload the Power Station’s capacity. Exceeding 
the wattage/amperage capacity may damage the power 
supply and/or electrical devices connected to it.

 

Do not connect Power Station output to a building’s 
electrical system.

 

Do not use this unit if you do not understand these 
operating instructions.

 

Maintain the labels and nameplates on this Power Station. 
These carry important information. If unreadable or 
missing, contact our Champion Technical Support Team for 
a free replacement.

Summary of Contents for 100594

Page 1: ...mpionpowerequipment com READ AND SAVE THIS MANUAL This manual contains important safety precautions which should be read and understood before operating the product Failure to do so could result in se...

Page 2: ...nnect DC Solar Charge Harness 20 Recommended Solar Panels 21 Using APP Port 21 Operation 22 Using the Power Station 22 Standby Mode 22 LED Light 22 Connecting Electrical Loads 23 Resetting the Output...

Page 3: ...ort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this docu...

Page 4: ...ratings on the Power Station and accessory products you intend to use CAUTION In outdoor conditions this device is intended for temporary outdoor use only Reasonable care should always be exercised wh...

Page 5: ...wer tools Connect only to properly grounded outlets To reduce risk of damage to the electric plug and cord pull the plug rather than the cord when disconnecting the Power Station Never use the cord fo...

Page 6: ...rain snow damp or wet locations Do not overcharge the Power Station internal battery Always connect to properly grounded outlets Never use Power Station or charger in the presence of explosive atmosp...

Page 7: ...es and counties it may be illegal to dispose of these batteries in standard household waste To dispose the battery safely apply tape over any exposed connectors to prevent accidental shorting of the p...

Page 8: ...TS WATTS AU D MARRAGE DE CR TE 120V 60Hz 1600W 100594 XXXX 1600 3200 4500 1 USB Type C PD3 0 60W 1 USB Type C PD3 0 60W 2 USB A 2 USB A 1 USB Type C QC3 0 1 USB Type C QC3 0 5V 2 1A 1 Anderson Powerpo...

Page 9: ...electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices can result in electric shock Shield eyes Explosive gases...

Page 10: ...roduct uses lithium ion Li ion batteries Local state or federal laws prohibit disposal of Li ion batteries in ordinary trash In the United States and Canada a large network of over 30 000 battery drop...

Page 11: ...for 3 seconds to power ON OFF Press for 1 second to power AC outlets ON OFF Circuit Breaker Reset Push Parallel Connection s AC Output DC Output 12V Direct Current Ground Terminal Neutral Floating Ne...

Page 12: ...eld button 5x within three seconds 4 Plug in desired devices NOTICE To protect sensitive electronics as the Power Station s battery level drops below 30 THD Shield is designed to shut off AC power out...

Page 13: ...e 120V AC 60Hz 4 5A MAX Used to charge the Power Station from a regular wall outlet Uses included cord 7 DC Fast Charge MPPT Solar 10V 28V DC 25A MAX APP Anderson Power Pole DC Used to charge the Powe...

Page 14: ...ole May be used to supply electrical power for operation of 12 Volt DC 20 Amp electrical loads B z 12V DC 10A Regulated Automotive May be used to supply electrical power for operation of 12 Volt DC 10...

Page 15: ...11 11 120V The 120V AC outlets are powered on and ready for use when steady blue Steady red if overloaded or fault has occurred in 120V AC inverter or outlets see Resetting the Output section 12 THD...

Page 16: ...to charge to full 0 watts out battery is at 10 H 1 2 W Charging Watts Example 384 Watts charging in 0 watts out battery is at 10 1 2 W W Discharging Hours Example 2 0 Hours to empty 0 watts in batter...

Page 17: ...HD steady red AC output shut off due to THD above 5 1 2 W W THD Shield Disabled THD 5 Example THD Shield disabled icon will be steady blue when THD is below 5 AC output will not shut off until battery...

Page 18: ...experiencing a fault See figure to the right 12V DC USB Port Fault Example Fault in 12V DC port location 1 APP and USB port location 3 USB PD Check devices cables or lower load Press overload reset bu...

Page 19: ...pt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause und...

Page 20: ...itive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations Charging From Wall NOTICE The Power Statio...

Page 21: ...Solar Panel 200 Watt 12 Volt 200 MC4 Bluetti SP120 120 MC4 Bluetti SP200 200 MC4 ECOFLOW EFSOLAR 160W 160 MC4 Any solar panel rated between 10 28V with MC4 or APP connectors can be used The Power Stat...

Page 22: ...n a pure sine wave 5 THD The letters THD will appear in red See THD Shield Total Harmonic Distortion section 4 To turn THD Shield off press THD Shield button 5x within three seconds 5 Plug in desired...

Page 23: ...C outlets 1 Unplug all devices 2 For AC output errors only Check to see if Power Station s circuit breaker is tripped If tripped push in to reset 3 Press the reset button 4 If overload is due to high...

Page 24: ...Management Use the following formula to convert voltage and amperage to watts Volts Amps Watts To prolong the life of your Power Station and attached devices follow these steps to add electrical load...

Page 25: ...ly with water No user serviceable parts for maintenance required Water can enter the Power Station through the cooling slots and damage the Power Station electronics 1 Use a damp cloth to clean exteri...

Page 26: ...5 3 cm Width 10 8 in 27 5 cm Height 12 3 in 31 3 cm Battery Specifications Chemistry Lithium ion NMC Pack Rated Output Voltage 46 8 Pack Max Output Voltage 55 Pack Capacity 1638 Wh Single Cell Equival...

Page 27: ...perature warning light Turn the unit off place it in the shade or a cooler area and let it cool down Check that the unit is not overloaded Unit is too cold Check display for flashing red Low Temperatu...

Page 28: ...you reach 440W of charging power Unit is nearing 100 battery level and is slowing down to a safer charging rate The charging power and rate is reduced as the battery level gets closer to 100 to safely...

Page 29: ...ot apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abused loaded beyond the product s limits modified installed improperly or connected inco...

Reviews: