1
REV 73500i-20140522
ENGLISH
73500i
ASSEmbLY ANd OPERATION
This kit is intended for use on Champion Power
Equipment 2000 Watt Inverter Generators.
Please refer to your Inverter Owner’s Manual for safety
rules, start up and shut down procedures, specifications
and troubleshooting.
1. The two generators may be stacked one on top of the
other by aligning the lower pads and upper pockets at
each corner of the generators.
Setup and Operation
2. Disconnect or turn off all electrical loads from both
generators.
3. The ECON switch must be in the same position on
both generators.
4. Remove caps from the power leads
5. Plug one pair of power leads (B), communication
cable (A), and ground wire (C) to inverter #1.
6. Plug the other pair of power leads (B), communication
cable (A), and ground wire (C) to inverter #2.
7. Align pins of the communication cable when
connecting (A).
8. Start engines of both inverters according to your
Inverter Owner’s Manual. Observe the green output
indicator light on both generator panels – The light
will blink during start up. When the light is steady
you may connect devices.
9. Connect devices to parallel panel or generator panel
receptacles. Loads up to 25 amps may be connected
to the parallel kit receptacles. Individual loads
connected to generator panels must be less than the
20 amp panel receptacle rating.
10. The total electrical load must not exceed 25 amps
(3000 watts).
11. Follow the instructions in your Inverter Owner’s
Manual for turning off the generators.
12. Pull “sleeve” of communication cable to disconnect.
A
C
b