background image

Champion Cooler 

5800 Murray St.

Little Rock, AR 72209

www.championcooler.com

Portable Evaporative Cooler

Safety Rules

1.  Unit must be in the Off Position and Unplugged from power receptacle when performing any mainte-

nance.

2.  To reduce the risk of electric shock, plug unit into a properly grounded 120 Volt A.C., 60 Hz receptacle.
3.  To reduce the risk of electric shock, install only on a circuit protected with a Ground Fault Circuit Inter-

rupter (GFCI).

4.  This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for their safety.  Children should be 
supervised to ensure that they do not play with the appliance.

 

WARNING:  To reduce the risk of fi re or electric shock, do not use this fan with any “solid-state 

fan speed control device.”

110489-7
1/10

Evaporative Cooling

Evaporative cooling is an economical way to cool.  Air is cooled  while being drawn across wet evapora-
tive media.  The movement of this fresh cooled air over the skin is what makes it feel cool.  It is important 
when using an evaporative cooler in an enclosed space to have adequate exhaust by opening windows, 
doors, etc.  Without an outlet to exhaust the air, humidity will build up in the enclosed space and the 
unit will not cool adequately.  It is preferable to have an opening behind the unit to bring in fresh air and 
another opening across the room to exhaust and help move the air.

Read And Save These Instructions

NOTICE:  This Product May Temporarily Produce An Odd Odor When First 
Turned On.  This Is NORMAL And Will Dissipate After A Few Hours.  

If you have any problems with this product, please call 1-800-643-8341 
BEFORE returning it to your retailer.

Model

CP25

Summary of Contents for CP25

Page 1: ...nce WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device 110489 7 1 10 Evaporative Cooling Evaporative cooling is an economical way to cool Air is cooled while being drawn across wet evapora tive media The movement of this fresh cooled air over the skin is what makes it feel cool It is important when using an evaporative cooler in a...

Page 2: ...inter of the indicator will be in the full position with water near the top of the reservoir As the water level is decreased in the unit the indicator will fall in the window until it reaches the Low indicator Power To Unit Refer to the control panel in figure 3 for the following instructions When the unit is plugged into an outlet the power indicator on the display will be red Pressing the power ...

Page 3: ...oncooler com This limited warranty applies to the original purchaser only Register your product online at www championcooler com eac onlineregistration eac htm Clean Replace Evaporative Media The evaporative media should be cleaned twice a season or when needed To clean the media rinse with clean water Light scrubbing might be necessary Be careful not to damage media After about 2 years or when it...

Page 4: ...be defective Replace pump Check that unit is plugged into a 120V power receptacle Check the fuse or breaker If connected to a GFCI outlet check if it is tripped Replacement Parts No Description CP25 1 Evaporative Media 110132 4 2 Evaporative Media Frame Assembly 110875 3 3 Set Of 4 Keepers 110871 4 Pump 110440 1 5 Drain Plug 110698 1 6 Swivel Casters Non Locking 110822 6 7 Swivel Casters Locking 1...

Page 5: ...gan con el aparato ADVERTENCIA Para reducir el riesgo de incendio o toques eléctricos no use este ventilador con ningún dispositivo de estado sólido para controlar la velocidad del ventilador Enfriamiento Por Evaporación El enfriamiento por evaporación es una manera económica de enfriarse El aire se enfría mientras se traza a través de un filtro mojado El movimiento de este aire enfriado fresco so...

Page 6: ...ando está lleno de agua Cuando el nivel de agua se disminuye en la unidad el indicador caerá hasta que llega a la posición Low Poner En Marcha La Unidad Para las instrucciones siguientes refiere a la figura 3 del panel de control Cuando se enchufa la unidad el indicador encendido iluminará rojo Al presionar el botón encendido pondrá en marcha la unidad en el modo de ventilador alto El indicador en...

Page 7: ...itada La presente garantía se extiende al comprador original de un enfriador evaporativo instalado y utilizado bajo condiciones normales No cubre daños ocurridos por accidente descuido o abuso por parte del propietario No autorizamos que ninguna otra persona o representante asuma por nosotros cualquier otra o diferente responsabilidad en relación con este producto Términos y Condiciones De La Gara...

Page 8: ...uosa Reemplace la bomba Compruebe que la unidad está enchufada en un receptáculo de 120 voltios Compruebe el fusible o el cortacircuito Si está conectado con un enchufe de GFCI compruebe si se desconectó Piezas De Repuesto n Descripción CP25 1 Filtro 110132 4 2 Montaje De Armazón Del Filtro 110875 3 3 Equipo De 4 Sujetadores 110871 4 Bomba 110440 1 5 Tapón De Goma 110698 1 6 Rueda Giratoria Sin Fr...

Reviews: