Maintenance Procedures (cont’d)
Temperature Switch
The Temperature Switch is located below the Oil
Filter in the tee of the Oil Tube going to the Cooler.
The Temperature Switch reads the oil temperature
of the unit. If the oil temperature reaches 105ºC
(220ºF) the unit will shut down, please refer to Page
26 for corrective action
To replace the Switch, please order ‘
DSC-002801
’.
Temperature
Switch
Anti-Rotation
Switch
Anti-Rotation Switch
The Anti-Rotation Switch is set to send an error to
the PLC once the pressure read at the Switch has
reached approx. 8 psi and the unit will shut down.
This prevents the Air End from rotating in the wrong
direction. Please refer to Page 26 for corrective
action.
The Anti-Rotation Switch is located on the Motor
side of the Air End. To replace the Switch, please
order ‘
DSC-102
’.
Anti-Rotation
Switch