‘CSC15’ Controller (cont’d)
Typical Operating Display
Typical information shown on the display is presented below.
Unit has power to it, but the Switch is in the ‘OFF’ position and the Unit is ready to start.
When the Switch is switched to ‘ON’ position, the Unit will idle for 5 seconds before it
begins to compress air.
After the Unit has idled for 5 seconds, the Unit will begin compressing air.
Once the Unit has reached the maximum pressure of 145 psi, it will remain running, but will
be in an Idle mode for 1 or 3 minutes depending on rate of pressure decay, it will not
compress air.
After the Unit runs in the unload state, the Unit will shut down and it relieves pressure in
the air end for 60 seconds. Once this blowdown time of 60 seconds expires and if there is
an air demand, the Unit will start again.
After 2000 hours of running, “Service Due’ message will appear on the display. This
indicates that the Unit requires service. Please refer to the Maintenance Schedule on
page 14 of this manual for the required service.
Resetting the Service Alarm
The D5 compressor must be serviced every 2000 hours. The Controller is programmed to count down from 2000
hours to 0 hours. Once it reaches 0 hours, the Red LED light on the control panel cover flashes in slow frequency
and an error message appears on the Controller screen, this indicating that service is due.
Once the servicing of the Unit has been completed, the Timer must be reset to 2000 hours.
1.
Turn the Compressor off by turning the On/Off Switch to the
‘
OFF
’ position.
2.
Remove the service door on the right-hand side of the unit.
3.
Press the ‘Service Reset’ button, the arrow on the left shows
the location of the Service Reset button,.
4.
Turn the Compressor on by turning the On/Off Switch to the
‘
ON
’ position
5.
Verify that the alarm has been cleared & the Fault Light is no
longer flashing.
6.
Replace the service door.