19-11/16"
20-9/16"
3/4HP Recirculating Pump
19-1/8"
16-5/16"
10"
32-3/8"
11"
2
3/4HP
11-3/16"
2HP
36-7/8"
20-7/8"
6-1/4"
4
3
38-1/16"
57-3/4"
12-1/16"
5-3/4"
1 -13/16"
15-1/8"
18-1/4"
12-1/4"
23-1/4"
33"
25-15/16"
60-5/16"
A
4
2
3
5HP
B
1-15/16"
3/4HP
D
C
F
2HP
G
E
5 Hp - 30" Pulper
Waste Handling System
P5-30 PULPER
24"
FLOORLINE
8"
1
48"
16"
Front View
9"
8"
4"
Front
View
Front View
Top View
Side View
P5-30 with Optional
Recirculating Pump
Mounted on Front of
Water Extractor
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 800/532-8591 • Fax: 336/661-1979 • www.championindustries.com
P5-30 w/ 3/4 Hp Recirculating Pump
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
31
40
40
240/60/3
29
40
40
480/60/3
15
20
20
P5-30 w/o Recirculating Pump
Minimum
Maximum
Supply Ckt.
Overcurrent
Elec.
Rated
Conductor
Protective
Specs.
Amps
Ampacity
Device
208/60/3
27
35
35
240/60/3
26
35
35
480/60/3
13
20
20