background image

201108 - POwER STATiON PARALLEL KiT

iMPORTANT SAfETY iNSTRUCTiONS

4

iMPORTANT SAfETY iNSTRUCTiONS

 

wARNiNG

Cancer and Reproductive Harm – www.P65Warnings.ca.gov

 

wARNiNG

Read all safety warnings and all instructions. Failure to follow 
the warnings and instruction may result in electric shock, fire 
and cause serious injury. Save all warnings and instruction.

 

DANGER

Parallel kit generates powerful voltage.

Keep your parallel kit in a dry, well-ventilated area when in 
use.

Do not operate the parallel kit with a damaged cord, plug, or a 
damaged output cable. Use only Champion electrical cords for 
proper application.

Do not allow children or unqualified persons to operate or 
service the parallel kit.

Do not operate parallel kit in wet conditions. To avoid short 
circuits or electric shock do not allow unit to get wet. In the 
event the unit does get wet, let the unit dry completely before 
using.

Always use a ground fault circuit interrupter (GFCI) in damp 
areas and areas containing conductive material such as metal 
decking.

Do not allow fluids to flow into parallel kit. Corrosive or 
conductive fluids, such as seawater, industrial chemicals, 
bleach or bleach containing products can cause a short circuit.

This equipment has internal arcing or sparking parts which 
should not be exposed to flammable vapors or liquids.

 

wARNiNG

To avoid fire or electrical shock hazard, observe all ratings on 
the parallel kit and accessory products you intend to use.

 

CAUTiON

This device is intended for temporary use outdoors and 
reasonable care should be exercised when using this device in 
damp conditions.

 

wARNiNG

Do not use parallel kit for medical and life support uses.

In case of emergency, call 911 immediately.

NEVER use this product to power life support devices or life 
support appliances.

NEVER use this product to power medical devices or medical 
appliances.

Inform your electricity provider immediately if you or anyone in 
your household depends on electrical equipment to live.

Inform your electrical provider immediately if a loss of power 
would cause you or anyone in your household to experience a 
medical emergency.

 

wARNiNG

Parallel kit produces heat. Skin burns can occur on contact.

Do not touch hot surfaces.

Allow equipment to cool before touching.

 

wARNiNG

Exceeding the parallel kit’s running capacity can damage the 
parallel kit and/or electrical devices connected to it.

DO NOT overload the parallel kit.

DO NOT tamper or modify the parallel kit in any way.

 

wARNiNG

Improper treatment or use of the parallel kit can damage it, 
shorten its life or void the warranty.

Use the parallel kit only for intended uses.

DO NOT expose parallel kit to moisture, dust, or dirt.

DO NOT allow any material to block the cooling slots.

If connected devices overheat, turn them off and disconnect 
them from the parallel kit.

DO NOT use the parallel kit if:

 

Electrical output is lost

 

Equipment sparks, smokes or emits flames

 

Equipment vibrates excessively

Summary of Contents for Para LINK 201108

Page 1: ...re operating the product Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual are as accurate as know...

Page 2: ...TABLE OF CONTENTS Introduction 3 Safety Definitions 3 Important Safety Instructions 4 Safety Symbols 5 Controls and Features 7 Control Panel 7 Assembly and Operation 8 Paralleling Two Power Stations 8...

Page 3: ...fort has been made to ensure the accuracy and completeness of the information in this manual at the time of publication and we reserve the right to change alter and or improve the product and this doc...

Page 4: ...serve all ratings on the parallel kit and accessory products you intend to use CAUTION This device is intended for temporary use outdoors and reasonable care should be exercised when using this device...

Page 5: ...ked to comply with ANSI Z87 1 Ground Consult with local electrician to determine grounding requirements before operation Electric Shock Failure to use in dry conditions and to observe safe practices c...

Page 6: ...t Important Safety Instructions 6 SYMBOL MEANING Open Flame Alert Keep away from fuel smoking open flames sparks pilot lights heat and other ignition sources Wet Conditions Alert Do not operate parall...

Page 7: ...1 Circuit Breakers Push Reset Protects the generator against electrical overloads 2 Power Indicator Illuminates green when power is being supplied to the parallel kit RECEPTACLES A t 120V AC 30A RV NE...

Page 8: ...s Paralleling Two Power Stations 1 Ensure both Power Stations are turned off and all electrical loads are disconnected before installing parallel kit 2 Lift open the parallel kit storage cover and rem...

Page 9: ...Stations up to the receptacles rated amperages Never exceed the specified rated capacity of the receptacle 9 Turn off and unplug connected devices before turning the Power Stations off CAUTION Do not...

Page 10: ...n not in use neatly wrap the cables and store them in the parallel kit s storage compartment SPECIFICATIONS Specifications Model 201108 Volts AC 120 Frequency 60 Hz Phase Single Weight 4 3 lb 1 97 kg...

Page 11: ...part or the equipment as a whole Installation Use and Maintenance This warranty will not apply to parts and or labor if the product is deemed to have been misused neglected involved in an accident abu...