13-11-614 Page 55
CAUTION
Ensure that the PLC “run/stop” mode selection switch remains in the “run” position at all times
– except during reprogramming. Failure to do so will halt the timed operation of the RO Filter
System and will damage its membrane by fouling.
RO System Specifications :
Clean water flow capacity: 73 gpd (192ml/min) at 50 psig, 70
°
F, 150 TDS raw feed water.
94 gpd (247ml/min) at 90 psig, 70
°
F, 150 TDS raw feed water.
Effect of water temperature of on clean water production: 1.8% flow change for every degree of temperature change
above (+) or below (-) 70
°
F rating.
Effect of water pressure on clean water production: 1.7% flow change for every psig of pressure change above (+)
or below (-) a known (e.g., 90 psi or 50 psi) rating.
Working pressure:
40 to 100 psig.
Working temperature:
40
°
F to 104
°
F.
Holding tank capacity:
7.0 gal @ 20 psig membrane air pressure, 90 psig feed.
6.0 gal @ 20 psig membrane air pressure, 50 psig feed.
Holding tank evacuation time:
3.5 minutes when filled with 90 psig feed.
2.5 minutes when filled with 50 psig feed.
RO membrane design:
spiral wound TFA
Sediment prefilter: 5-micron element, spun PPE w/o end caps, typical 4 psid loss clean at full flow.
Carbon prefilter: 10-micron charcoal element, PPE wrap/netting, w/end caps, typical 1 psid loss clean at full flow.
Rejection levels of various water-soluble compounds:
Calcium
96-98%
Copper
98-99%
Hardness
95-98%
Manganes e
98-99%
Iron
95-98%
Lead
96-98%
Silica
85-90%
Sodium
87-98%
Sulfate
98-99%
Incoming raw water allowable contaminant concentrations:
Total Dissolved Solids (TDS):
1800 ppm
Iron
0.4 ppm
Hardness (non-carbonate)
293 ppm
Hydrogen Sulfide
.05 ppm
Manganese
.1 ppm
Silica
100 ppm
Turbidity
20 FTU
pH
6.5 to 8.5
Summary of Contents for ROTORCHAMP EWF99C-100
Page 7: ...13 11 614 Page 7 Figure 1 2 PACKAGE ILLUSTRATION AIR COOLED 309EWF797 A Ref Drawing ...
Page 8: ...13 11 614 Page 8 Figure 1 3 PACKAGE ILLUSTRATION WATER COOLED 310EWF797 A Ref Drawing ...
Page 9: ...13 11 614 Page 9 Figure 1 4 AIR COOLED SCHEMATIC 307EWF797 A Ref Drawing ...
Page 10: ...13 11 614 Page 10 Figure 1 5 WATER COOLED SCHEMATIC 308EWF797 A Ref Drawing ...
Page 29: ...13 11 614 Page 29 Figure 4 2 FLOW CHART FOR SETUP PROGRAMMING 300EWC1255 Ref Drawing ...
Page 43: ...13 11 614 Page 43 303EWF546 A Ref Drawing Page 2 of 2 ...
Page 45: ...13 11 614 Page 45 304EWF546 A Ref Drawing Page 2 of 2 ...
Page 47: ...13 11 614 Page 47 305EWF546 A Ref Drawing Page 2 of 2 ...