13- 11- 605
Page 43
2.
Pressure drop through a filter with a freshly
cleaned element is below three (3) inches (76
mm) of water with the compressor running at full
load -- this would indicate a rupture or crack.
Inlet Tube
-- Inspect the inlet screen and tube for dirt
accumulation each time the filter is serviced. Clean the
tube when required by ramming a clean dry cloth
through the tube. Wipe the inside of the filter body to
remove any dirt falling from the inlet tube before rein-
stalling the element.
Causes of short element life include: severe dust
conditions, infrequent servicing, improper cleaning, or
contamination by oil or chemical fumes.