Leak Check

WARNING

• Perform all leak tests outdoors.

• Extinguish all open flames.

• NEVER leak test when smoking.

• Do not use the heater until all connections have been leak

tested and do not leak.

Make 2-3 oz. of leak check solution (one part liquid

dishwashing detergent and three parts water).

Apply several drops of solution where hose attaches
to regulator.

Apply several drops of solution where regulator

connects to Cylinder.

Make sure all Patio Heater & Light valves are OFF.

Turn Cylinder Valve ON.

If bubbles appear at any connection, there is a leak.

Turn Cylinder Valve OFF.

If leak is at Hose/Regulator connection: tighten

connection and perform another leak test. If bubbles
continue appearing should be returned to Hose’s place
of purchase.

If leak is at Regulator/Cylinder Valve connection:

disconnect, reconnect, and perform another leak

check. If you continue to see bubbles after several

attempts, cylinder valve is defective and should be

returned to cylinder’s place of purchase.

If

NO

bubbles

appear

at

any

connection,

the

connections are secure.

.

Turn Cylinder Valve OFF.

NOTE: Whenever gas connections are loosened or

removed, you must perform a complete leak test.

.

Complete installation.

Operation

DANGER

• CARBON MONOXIDE HAZARD

• For outdoor use only. Never use inside house, or other

unventilated or enclosed areas. This heater consumes air

(oxygen). Do not use in unventilated or enclosed areas to

avoid endangering your life.

Caution: Do not attempt to operate until you have read

& understand all General Safety Information in this

manual and all assembly is complete & leak checks

have been performed.

Regulator / Cylinder
     Connection

Hose / Regulator
   Connection

Summary of Contents for HSS-A-GH

Page 1: ...SKU NUMBER 70005001 IMPORTANT Read this manual carefully before assembling using or servicing this heater Keep this manual for future reference ANSI Z83 26 2007 CSA 2 37 2007 Gas Fired Outdoor Infrar...

Page 2: ...mechanical or fueled equipment 1 DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates an imminently hazardou...

Page 3: ...I Z223 1 In Canada installation must conform to local codes If no local codes exist follow the current National standards of CANADA CAN CGA B 149 2 DANGER CARBON MONOXIDE HAZARD This heater is a combu...

Page 4: ...sources or where temperatures exceed 120 degrees F 49 C Propane vapors are heavier than air and canaccumulate in low places If you smell gas leave the area immediately Never install or remove propane...

Page 5: ...1 Attach Support Brackets to Base Attach three Support Brackets loosely to Base with three medium bolts downward through Support Brackets into the Base 3 Req d Medium Bolts Installation process Revers...

Page 6: ...Load Cylinder Housing onto Post Load Cylinder Housing onto Post Slide Cylinder Housing down Step 4 Attach Reflector Studs to Screen Cover Insert 3 Reflector Studs 3 Flat Washers Tighten studs securely...

Page 7: ...each screw prior to further assembly and retighten after sections are aligned Slide two Reflector Panels together Insert one Small Screw Slide one Small Flat Washer over threaded end of screw and scre...

Page 8: ...10 W C is required for purpose of input adjustment The minimum hourly of 17000 Btu is required input rating for a heater for automatic operation at ratings less than full input rating You must provide...

Page 9: ...ce of purchase If leak is at Regulator Cylinder Valve connection disconnect reconnect and perform another leak check If you continue to see bubbles after several attempts cylinder valve is defective a...

Page 10: ...s Pilot must be lit before Main Burner can be started 5 Push and release the igniter button until pilot flame is visible through Viewing Hole 6 Once the pilot is lit continue to depress the control Kn...

Page 11: ...and continue to turn it clockwise to OFF Turn Cylinder Valve clockwise to OFF and disconnect Regulator when heater is not in use Note After use some discoloration of the emitter screen is normal Oper...

Page 12: ...inder Supply hose is bent or kinked Straighten hose Control knob fully ON Check burner and orifices for blockage Carbon build up Dirt or film on reflector and burner screen Clean reflector and burner...

Page 13: ...The manufacturer warrants to the original consumer purchaser only that this product Model HSS A GH shall be free from defects in workmanship and materials after correct assembly and under normal and...

Page 14: ...SCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES Repair or replacement of defective parts is your exclusive remedy under the terms of this limited warranty Manufacturer will not be responsible fo...

Reviews: