background image

14 

Attachment2 Warranty Conditions

Attachment2 Warranty Conditions

Attachment2 Warranty Conditions

Attachment2 Warranty Conditions 

 

 

 

 

Warranty conditions 

warranty

 

Within 18 months after buying date 

 

Warranty terms

 

一、

一、

一、

一、    

In  the  warranty  period,  if  the  product  failure  occurs  under  normal  use,  the 

user can produce this warranty card and invoice or receipt (copy) to enjoy free 

repair service.   

二、

二、

二、

二、    

In  the  following  situations,  the  repair  is  charged.  A  certain  material  fee, 

maintenance fee and freight occurs: 

1

 

The product failure occurs under normal use, but not within the warranty 

period. 

2

 

Not produce this warranty card or the warranty card is missed, altered or 

unclear filling in. 

3

 

Using  under  non-normal  conditions,  such  as  man-made  damage,  high 

temperature,  pressure,  humidity.  Normally  a  certain  maintenance  fee  is 

charged based on different situations.   

4

 

Failure or damage caused not by the product quality problem. 

5

 

If  the  user  doesn’t  operate  the  instrument  according  to  the  instructions 

and written precautions, then the failure or damage occurs. 

三、

三、

三、

三、    

Our company will not repair the instrument in the following circumstances

 

1

 

Make unauthorized repair or modifications to the instrument. 

2

 

The product is not manufactured or sold by our company.   

 

Please keep this part.Cut down the below part and send it to us

 

Cut along the dotted line and send it back to our company

 

 

 

 

 

Summary of Contents for mw3200

Page 1: ...MW3200 Optical Multi Meter Manual Changzhou Myway Electronics Co Ltd...

Page 2: ...oned in this manual belong to MW MW has the right of the manual interpretation Trademarks All trademarks mentioned in this manual are registered property of MW Explanation The content of this manual i...

Page 3: ...cifications 2 Technical Specifications 3 Instrument Introduction 4 5 Instructions for Use 5 17 Troubleshooting 17 Care and Maintenance 18 Quality Assurance 18 Attachment 1 Product Warranty Card 19 Att...

Page 4: ...rk and cable television Features Features Features Features Easy mode switching function Stable Output light Automatic switching function of the internal source wavelength Detection of the frequency l...

Page 5: ...1310 1550 customizable Typical Output Power dBm 5 customizable Stability dB 30min 20 0 1dB Modulation frequency Hz CW 270Hz 1KHz 2KHz O O O Other parts ther parts ther parts ther parts Power supply 3...

Page 6: ...Standard Configaration Standard Configaration 1 MW3200 instrument 1pc 2 instructions 1copy 3 Data disc 1pc 4 Mini USB data cable 1pc 5 5V USB adapter 1pc 6 1 5V USB adapter 3pcs 7 Cleaning Swbs 1pack...

Page 7: ...tion Introduction Function Introduction Turn on or off the meter Switching wavelength under test Turn on or off the backlight data testing storage Viewing automaticswitching of source wavelength delet...

Page 8: ...l have no auto off function image 5 1 Image 5 1 After turning on the instrument comes into power meter mode After turning on the instrument comes into power meter mode After turning on the instrument...

Page 9: ...mage 5 4 3 Short press button start REF function When the current tested value is set or changed to reference value the instrument comes to relative power measurement and the top right corner of the s...

Page 10: ...on under power meter mode SAVE function will respond Data storage short press the button to save the current test data press button for once the screen will show storage serial number press again to c...

Page 11: ...ce mode Source mode Source mode 1 button Sequentially switching to the meter internal source wavelength 2 button button turn on or off the laser output in the source image 5 9 Image 5 9 3 button After...

Page 12: ...m the laser output wavelength in the meter source module will be changed to 1550nm automatically On the contrary when the test wavelength in the power meter module is different from the output wavelen...

Page 13: ...mode press and at the same time U 01 will appear on the screen top right corner indicating that the meter has come to power value calibration mode Press and to increase or decrease the absolute optica...

Page 14: ...se this function to avoid the meter measurement deviation Troubleshooting Troubleshooting Troubleshooting Troubleshooting Fault Situations Fault Situations Fault Situations Fault Situations Possible C...

Page 15: ...m within warranty time it will be properly repaired or changed But in any case the company responsibility is within the product purchase price 8 2 If the instrument has problems in the use please see...

Page 16: ...oduct serial number purchase date User name Tel Fax Address Zip code E mail Stamp Please keep this part Cut down the below part and send is to us Cut along the dotted line and send it back to our comp...

Page 17: ...t produce this warranty card or the warranty card is missed altered or unclear filling in 3 Using under non normal conditions such as man made damage high temperature pressure humidity Normally a cert...

Reviews: