background image

 

44 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Manufactured by: 

Charder Electronic Co., Ltd. 

No.103, Guozhong Rd., Dali Dist.,   

Taichung City 412, Taiwan (R.O.C.) 

 

 

 

CD-IN-00052 [REV0002] 07/2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please keep the instruction manual at hand all the time for future reference 

 

MS 3850 

Medical Scale

 

USER MANUAL 

Summary of Contents for MS 3850

Page 1: ...der Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C CD IN 00052 REV0002 07 2018 1 Please keep the instruction manual at hand all the time for future reference MS 3850 Med...

Page 2: ...S DECLARATION 8 SPECIFICATION 13 PANEL 15 LCD SYMBOL DESCRIPTION 16 SYMBOLS Information 16 Operation 17 SETTING UP MS3850 22 PRINT function and data transmission 23 ASSEMBLY OF BRACKET 27 PARTS LIST...

Page 3: ...tructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions These batteries should be...

Page 4: ...ns power supply before cleaning MAINTENANCE The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is...

Page 5: ...into your scale please read the following important guidelines Always be sure that the display shows Zero before use if it does not then please press the ZERO key The device is designed to detect whe...

Page 6: ...erms and conditions listed in the yearly Warranty Program Return Policy Our warranty service program includes the following 1 Technician repair service under warranty or at a service maintenance charg...

Page 7: ...underneath the scale and power on again If the scale continues to show the error message it indicates a fault with the electronics AD Error This indicates there is a fault with the scale s software a...

Page 8: ...s RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flic...

Page 9: ...e wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2kV for power supply lines 1kV f...

Page 10: ...rms Portable and mobile RF communications equipment should be used no closer to any part of the MEDICAL SCALE MS3850 including cables than the recommended separation distance calculated from the equat...

Page 11: ...s Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless te...

Page 12: ...f transmitter W 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated a...

Page 13: ...ng Temp and Humidity 5 C 35 C 15 85 RH Transport Storage Temp and Humidity 20 C 60 C 10 95 RH Key Functions UNIT SEND ON OFF ZERO HOLD BMI TARE BSA Power Supply 6 AA size batteries 12V AC Adaptor Stan...

Page 14: ...S 4971 1 5 Tapping screw M3 10 3 6 User manual CD IN 00052 1 7 USB cable 1 8 12V Adaptor 1 9 Plastic anchor 1 white 2 10 Screw 4 20 2 31 ASSEMBLY INSTRUCTION OF HANDRAILS Step 1 Fix no 2 fixing plate...

Page 15: ...to switch measuring unit from kg and lb SEND Send data key Press to send measuring data to PC ON OFF ZERO Switch on and off Press button to turn it on To turn it off press and hold the button for 1 se...

Page 16: ...rmation Stability sign Negative sign Zero indication Battery symbol 29 SM 3461 R NO Item Drawing Qty 1 Handrail bar SS 8300B 1 2 Fixing plate SS 8311 4 3 Socket button head cap screw M6 21 10 4 Pole A...

Page 17: ...ware version and then 0 0 kg Switching off Press and hold for 3 seconds to switch scale off Zero the scale Press while scale is on to zeroing the scale 2 Straight weighing 1 Place weighing object pers...

Page 18: ...ading will remain on the display 5 Press key again to return the scale to the normal weighing mode 6 HOLD function can be activated before or after place the weight on the SCALE 4 Weighing with tare T...

Page 19: ...0kg USER HEIGHT 170 0cm USER B M I 24 2 01 01 2013 10 00 19 4 1 2 Clear the tare Press to clear tare weight The symbol NET disappear The gross weight appears in the display 5 Weighing with BMI For BMI...

Page 20: ...s 0 5 m 9 years 1 07 m 10 years 1 14 m 12 13 years 1 33 m Women 1 6 m Men 1 9 m There was an average BSA of 1 73 m for 3 000 cancer patients from 1990 to 1998 in a European Organisation for Research a...

Page 21: ...ge BSA of 1 79 m for 3 613 adult cancer patients in the UK Among them the average BSA for men was 1 91 m and for women was 1 71 m However there is some evidence that BSA values are less accurate at ex...

Page 22: ...need to consult with local computer accessories dealer to select the proper USB cable length that is most suitable to work environment for best performance then connect the cable first between the PC...

Page 23: ...der Electronic Co Ltd No 103 Guozhong Rd Dali Dist Taichung City 412 Taiwan R O C CD IN 00052 REV0002 07 2018 1 Please keep the instruction manual at hand all the time for future reference MS 3850 Med...

Page 24: ...S DECLARATION 8 SPECIFICATION 13 PANEL 15 LCD SYMBOL DESCRIPTION 16 SYMBOLS Information 16 Operation 17 SETTING UP MS3850 22 PRINT function and data transmission 23 ASSEMBLY OF BRACKET 27 PARTS LIST...

Page 25: ...tructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions These batteries should be...

Page 26: ...ns power supply before cleaning MAINTENANCE The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is...

Page 27: ...into your scale please read the following important guidelines Always be sure that the display shows Zero before use if it does not then please press the ZERO key The device is designed to detect whe...

Page 28: ...erms and conditions listed in the yearly Warranty Program Return Policy Our warranty service program includes the following 1 Technician repair service under warranty or at a service maintenance charg...

Page 29: ...underneath the scale and power on again If the scale continues to show the error message it indicates a fault with the electronics AD Error This indicates there is a fault with the scale s software a...

Page 30: ...s RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flic...

Page 31: ...e wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst IEC 61000 4 4 2kV for power supply lines 1kV f...

Page 32: ...rms Portable and mobile RF communications equipment should be used no closer to any part of the MEDICAL SCALE MS3850 including cables than the recommended separation distance calculated from the equat...

Page 33: ...s Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless te...

Page 34: ...f transmitter W 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated a...

Page 35: ...ng Temp and Humidity 5 C 35 C 15 85 RH Transport Storage Temp and Humidity 20 C 60 C 10 95 RH Key Functions UNIT SEND ON OFF ZERO HOLD BMI TARE BSA Power Supply 6 AA size batteries 12V AC Adaptor Stan...

Page 36: ...S 4971 1 5 Tapping screw M3 10 3 6 User manual CD IN 00052 1 7 USB cable 1 8 12V Adaptor 1 9 Plastic anchor 1 white 2 10 Screw 4 20 2 31 ASSEMBLY INSTRUCTION OF HANDRAILS Step 1 Fix no 2 fixing plate...

Page 37: ...to switch measuring unit from kg and lb SEND Send data key Press to send measuring data to PC ON OFF ZERO Switch on and off Press button to turn it on To turn it off press and hold the button for 1 se...

Page 38: ...rmation Stability sign Negative sign Zero indication Battery symbol 29 SM 3461 R NO Item Drawing Qty 1 Handrail bar SS 8300B 1 2 Fixing plate SS 8311 4 3 Socket button head cap screw M6 21 10 4 Pole A...

Page 39: ...ware version and then 0 0 kg Switching off Press and hold for 3 seconds to switch scale off Zero the scale Press while scale is on to zeroing the scale 2 Straight weighing 1 Place weighing object pers...

Page 40: ...ading will remain on the display 5 Press key again to return the scale to the normal weighing mode 6 HOLD function can be activated before or after place the weight on the SCALE 4 Weighing with tare T...

Page 41: ...0kg USER HEIGHT 170 0cm USER B M I 24 2 01 01 2013 10 00 19 4 1 2 Clear the tare Press to clear tare weight The symbol NET disappear The gross weight appears in the display 5 Weighing with BMI For BMI...

Page 42: ...s 0 5 m 9 years 1 07 m 10 years 1 14 m 12 13 years 1 33 m Women 1 6 m Men 1 9 m There was an average BSA of 1 73 m for 3 000 cancer patients from 1990 to 1998 in a European Organisation for Research a...

Page 43: ...ge BSA of 1 79 m for 3 613 adult cancer patients in the UK Among them the average BSA for men was 1 91 m and for women was 1 71 m However there is some evidence that BSA values are less accurate at ex...

Page 44: ...need to consult with local computer accessories dealer to select the proper USB cable length that is most suitable to work environment for best performance then connect the cable first between the PC...

Reviews: