background image

30 

 

Press 

[CLEAR]

 key to return to 

Normal Mode 

 

 

NOTE: Pre-tare weight must be under max capacity, otherwise screen will 
show 0.00 after 

[ENTER] 

key is pressed, and the operator will have to 

re-input pre-tare settings. 
 

F. Print 

If thermal printer is connected to indicator, results can be printed by 
pressing 

[PRINT] 

key.

Summary of Contents for MS2504

Page 1: ...1 USER MANUAL MS2504 Stand on Floor Scale Please keep the instruction manual at hand all the time for future reference...

Page 2: ...for 2019 Separate collection for waste of electrical and electronic equipment in accordance with Directive 2002 96 EC Indicates that device conforms to 93 42 EEC as amended by 2007 47 EC Medical Devi...

Page 3: ...rnational copyright law All content is licensed and usage is subject to written authorization from Charder Electronic Co Ltd hereinafter Charder Charder is not liable for any damage caused by a failur...

Page 4: ...A Indicator and Key Functions 23 B Display layout 24 IV Using Device 25 A Basic Operation 25 B Hold 25 C BMI 25 D Tare 26 E Pre Tare 27 F Print 30 V Device Setup 31 A Setting Time Date 31 B Device Se...

Page 5: ...n stable flat solid non slippery surface Usage on soft surfaces ex carpet may result in inaccurate results Ensure all parts are properly locked and tightened before operating the device Safety Instruc...

Page 6: ...gular maintenance and calibration Device does not require routine maintenance However regular checking of accuracy is recommended frequency to be determined by level of use and state of device If resu...

Page 7: ...et hands Do not crimp the power cable and avoid sharp edges Do not overload extension cables connected to the device Route cables carefully to avoid tripping Keep device away from liquids Do not remov...

Page 8: ...guidance RF emissions CISPR 11 Group 1 The device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electron...

Page 9: ...hospital environment Surge IEC 61000 4 5 1kV line s to line s 2kV line s to earth 1kV line s to line s 2kV line s to earth Mains power quality should be that of a typical commercial or hospital enviro...

Page 10: ...z 80 AM at 1 kHz 3 V m 80MHz to 2 7 GHz Portable and mobile RF communications equipment should be used no closer to any part of the device including cables than the recommended separation distance cal...

Page 11: ...150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separation distance between portable and mobile RF communications equipment and the MS2504 Stand on Floor Scale The device is i...

Page 12: ...frequency range applies NOTE2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people II Installation A...

Page 13: ...13 3 Attach third handrail to platform Tighten upper screws first Tighten side screws after...

Page 14: ...14 Attaching handrail 1 Attach handrail columns to platform 2 Attach handrail to column with screws NOTE securely tighten screws mounting handrail to column...

Page 15: ...15 Attaching indicator 1 Ensure screws securing indicator to handrail are tight bottom view...

Page 16: ...16 B Inserting Batteries 1 Open battery housing cover 2 Accessing batteries 3 Use either rechargeable battery pack or AA batteries Take out the battery housing...

Page 17: ...lled into the housing correctly 5 Install the battery housing into the compartment and make sure the right side of housing pin is facing towards inside of the connecting position Rechargeable Battery...

Page 18: ...s of if the device has been used Battery can be charged by plugging device s exclusive adapter into AC Connector Port After a long period in storage e g 3 months the battery should run a full cycle ch...

Page 19: ...19 C Using Adapter 1 Connect adapter to indicator before connecting to mains power supply 2 Disconnect adapter from mains power supply before unplugging adapter pin from indicator AC Connector Port...

Page 20: ...20 D Attaching Height Rod to Column Installation 1 Attach two fixing blocks to column 2 Attach height rod to fixing blocks using two screws...

Page 21: ...nnecting Digital Height Rod to indicator 1 Locate USB port on back of height rod 2 Connect USB cable 9 pin DIN to USB port on height rod 3 Locate 9 pin DIN port on bottom of indicator and connect USB...

Page 22: ...HM200D using ON OFF key If height display is not at 120cm press Reset key to calibrate to 120cm Calibrating Height Rod HM201D Slide measurement rod down completely Turn on HM201D using BMI key on ind...

Page 23: ...p to 5 4 PRE TARE Pre tare the known weight of an object ex chair before beginning measurement 5 TARE Allows user to deduct weight from reading after measurement 6 PRINT When printer or PC is connecte...

Page 24: ...24 B Display layout Definitions Stable symbol Indicate that weight is stable Zero symbol Weight is at zero Minor weight Weight under zero Low battery Battery needs to be charged or replaced...

Page 25: ...ex an active child Note if fluctuation is too severe average weight determination will be difficult and hold may not function correctly 1 Switch on the device normally 2 Press the HOLD key HOLD will b...

Page 26: ...late BMI based on change in height and weight NOTE Hold function can be used at this time if weight is unstable 5 Press BMI key to return to normal mode Category BMI kg m2 Risk of obesity related dise...

Page 27: ...Weight or Input Manually After pre tare weights have been stored they can be recalled by holding the PRE TARE key for 3 seconds A Load Weight DESCRIPTION EXAMPLE Press M1 5 key after loading weight o...

Page 28: ...hile digit is blinking Enter pre tare weight using 0 9 keys Ex to pre tare 5 0 kg of weight press 0 0 5 0 Ex to pre tare 13 5 kg of weight press 0 1 3 5 Press ENTER key to confirm the pre tare weight...

Page 29: ...ake a beep sound C Recall Pre Tare Weight DESCRIPTION EXAMPLE Press and hold PRE TARE key for 3 seconds Indicator will display pre tare value M1 first The pre tare value will flash Press numeral keys...

Page 30: ...tare weight must be under max capacity otherwise screen will show 0 00 after ENTER key is pressed and the operator will have to re input pre tare settings F Print If thermal printer is connected to in...

Page 31: ...onth followed by day using numeral keys 0 9 Ex December 25th is 12 25 Input 1 2 2 5 Press HOLD key once completed to proceed to time setting Time Setting Enter time 24hr format using numeral keys 0 9...

Page 32: ...ut off automatically after a certain period of time Auto off options 120 sec 180 sec 240 sec 300 sec off Press HOLD to toggle between time options and TARE to confirm selection Buzzer Beep When functi...

Page 33: ...ff Press HOLD to toggle between on off and TARE to confirm selection Wi Fi optional If device has Wi Fi module installed Wi Fi function can be turned on or off Press HOLD to toggle between on off and...

Page 34: ...ata Manager can be used to connect the device to a PC The software program can be downloaded from the Charder website LINK URL https www chardermedical com download htm 2 Connect USB cable to device i...

Page 35: ...BMI calculation into software if needed Press Clear to clear all input NOTE information can also be input after weight measurement 2 Conduct measurement If Auto is selected results will be transmitte...

Page 36: ...hanges and multiple measurements for the same subject we recommend not changing the default file name 2 Result example If previous results were saved in 20190201 csv new results also need to be saved...

Page 37: ...ng a printer connected to the PC VII Wireless Connection If the device has the wireless or bluetooth module installed the indicator can transmit measurement results wirelessly Please see Charder wirel...

Page 38: ...ng chemical electrochemical or electrical interference unless damage is attributable to negligence on the part of Charder If device is not covered under warranty a service maintenance charge will appl...

Page 39: ...software is set up properly as indicated in this manual Distributor support required If the following errors occur we recommend contacting your local Charder distributor for repair or replacement ser...

Page 40: ...aused by faulty loadcell or wiring Please contact distributor Counting Error too low Signal from loadcells too low Error normally caused by faulty loadcell or wiring Please contact distributor Zero co...

Page 41: ...ce Weight 20 8 kg Key Functions On Off Zero Print BMI Hold Pre Tare Tare Clear Enter 0 9 M1 5 Power Supply Rechargeable battery pack optional or 6 AA batteries adapter Operation Temperature Humidity 0...

Page 42: ...ead hex socket screws for columns M5 0 8 18 12 3 Washer head screws for handrail M5 0 8 38 3 4 Locknut for handrail M5 T 6 2 3 5 screws for indicator M4 0 7 8 3 6 washer for handrail M5x12x1 15 7 Rubb...

Page 43: ...43 C Power Adapter Standards Warning The device is only compatible with the power adapters specified in the dashed block below...

Page 44: ...directives 93 42 EEC as amended by 2007 47 EC Medical Device Directive 2014 31 EU Non automatic Weighing Instruments Directive Please see separate document showing on sticker of device for above CE ma...

Reviews: