battery 2# into socket 2 separately. Take one 8S battery and one 4S sample as following: 

 

Figure 2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications: 

 

Battery range: 3S-16S LiFePO4 battery pack   

 

Over discharge warning voltage: 

2.00~3.50V

 per cell, step 0.05V, default 3.00V 

 

Over charge warning voltage: 

3.40

~

3.90V 

per 

cell,

 

step 0.05V, default 3.70V 

 

Over  cell  voltage  difference  warning  voltage: 

0.010

~

0.500V 

per  cell,

 

step  0.005V,  default 

0.050V 

 

Over  temperature  warning:

  30~80

  step  1

default 50

 

 

Under  battery  gauge  (SOC)  warning: 

5~90%

 

step 1%, 

default 30%

 

 

Delay time when start to warnning:

2S

 

 

Warning time:

20S 

per period 

 

Accurate scope of the cell voltage: 

-5mV/+5mV

 

 

Cell Voltage display range: 0.50~4.99V

, NO display when under 0.50V 

 

Temperature display range:0.0

~99.9

℃, 

 

 

Display 0.0 when under 0.0

 

 

Display 99.9 when over 100

 

 

SOC indicator:   

 

RED area @ 0~15% of SOC   

 

YELLOW area @ 16~35% of SOC 

 

GREEN area @ 36~100% of SOC 

 

Pins distance: 2.54mm   

 

Size:70*65*11 ( L*W*T, mm)   

 

Weight: 30g 

 

Warning LED: 11000mCd, @ 2.0V, 20mA   

 

Warning beeper: 85dB @ 12V, 25mA 

 

Package: transparent heat shrink tube or Customized AL alloy case 

Socket 2 

SET 

Cell 1 

Cell 2 

Cell 3 

Socket 1 

DOWN    UP 

LED 

BEEPER 

Temperature sensor 

Temperature sensor 

Cell 4 

Cell 5 
Cell 6 

Cell 

Cell 

Cell 9 

Cell 10 

Cell 11 

Cell 12 

Alarm Port 

Summary of Contents for BM16LF

Page 1: ...trolled high performance Battery Monitor For 3S 16S LiFePO4 battery pack Chargery Power Co Ltd Head Office Add Chuangye Road Nanshan Shenzhen 518054 China Zip code 518054 Tel 86 755 2643 6165 Fax 86 7...

Page 2: ...nit can alarm When stop driving your bike or scooter you can check the lowest cell voltage so you can find the worst cell the lowest voltage cell New features BM16LF can indicate battery SOC or called...

Page 3: ...er into Program Setup menu In driving BM16LF can alarm loudly and a RED LED flash alternately when any cell voltage under over discharge warning voltage till the cell voltage over the value If the cel...

Page 4: ...gauge SOC warning 5 90 step 1 default 30 Delay time when start to warnning 2S Warning time 20S per period Accurate scope of the cell voltage 5mV 5mV Cell Voltage display range 0 50 4 99V NO display w...

Page 5: ...ACK LIGHT TIME Set up over charge warning voltage range 3 40 3 90V per cell step 0 05V default 3 70V During charge when any cell voltage over the value the unit will alarm Set up maximal cell voltage...

Page 6: ...output port signal ON means the collector connected to Ground Alarm output port signal OFF means the collector open Warning Please attention to the port voltage and current limit when use 30V 1A Erro...

Page 7: ...turing defect the accessory will be replaced or repaired Your selling dealer is your first point of contact for warranty issues Return postage costs are the responsibility of the user in all cases Ple...