3S-16S LiFePO4 battery Monitor and Saver BM16LF V3.0
www.chargery.com
page 6 total 7
Alarm Remind
If the device detects the alarm events, including
over charge, over discharge, over temperature and
over difference voltage, it can do:
1.
The buzzer beeps and LED flash.
2.
You can press UP or DOWN button check the
error information, as the following,
Error information
3.
At the same time Alarm port will output the presetting signal ON or OFF.
Alarm output port signal ON means the collector connected to Ground.
Alarm output port signal OFF means the collector open.
Warning:
Please attention to the port voltage and current limit when use (<30V, 1A)
Error Info.
Voltage High!
Vol. Diff High!
SOC LOW!
Temp1 High!
Temp2 High!
Any cell voltage over setup during charge, display Voltage High!
Any cell voltage under setup during discharge, display Voltage Low!
When cell voltage difference over setup during charge, discharge or
storage, display Vol. Diff High!
When battery pack SOC (State of Charge) under setup, display SOC Low!
When battery temperature over setup, display Temp1 or Temp2 High
!
ALARM port
VCC<30V