Charles Industries, Ltd. All rights reserved. Printed in the United States of America.
Step
Action
7.
Connect all wiring as shown in Figure 5, Figure 6 or Figure 7 based on the chosen wiring method as
follows:
H1, H2 & X1: Use UL Recognized #10 AWG insulated butt connectors for making the H1, H2 & X1 con-
nections. Crimp and tape each connection individually with UL Recognized electrical tape.
GND & X2: Use UL Recognized ring or captive spade terminals for making the GND and X2 connec-
tions at the GND screw.
SH: When wiring as an Isolation Transformer (Figure 5) use a UL Recognized insulated #6 AWG butt
connector for the SH (shield) connection. Crimp and tape the connection. When wiring as an Isolation
Transformer with Primary Ground Fault Protection (Figure 6) or as a Polarization Transformer
(Figure 7), use a UL Recognized ring or captive spade terminal for making the SH (shield) connection
at the GND screw.
8.
Tighten the cord grip connectors
9.
Reinstall the access cover.
H1
H2
SH
GND
X1
INPUT
OUTPUT
BLACK
WHITE
GREEN
WHITE
BLACK
(Line)
(Neutral)
(Neutral)
(Line)
WHITE
BLACK
GREEN
WHITE with STRIPE
BLACK with STRIPE
(Shore Grounding)
GREEN (Boat Grounding)
X2
Wire is fed through the cord grip connector.
I
N
P
U
T
O
U
T
P
U
T
Figure 5. Typical Wiring as an Isolation Transformer – Method 1 (see Figure 1 for Electrical Diagram)