www.charltonandjenrick.co.uk
5
LT8019
SECTION ONE Introduction (Users Instructions)
Consumer Protection Information
As manufacturers and suppliers of heating products, we take every care, as far as is reasonably practicable, that these
products are so designed and constructed as to meet the general safety requirement when properly used and installed.
To this end, our products are thoroughly tested and examined before despatch.
IMPORTANT NOTICE:
Any alterations that are not approved by the appliance manufacturer could invalidate the
approval of the appliance, operation of the warranty and could affect your statutory rights.
Health and Safety Notice
Important
This appliance could contain some of the materials, indicated below, that may be interpreted as being injurious to
health and safety. It is the users / installers responsibility to ensure that the necessary personal protective clothing is
worn when handling these materials, see below for information.
Artificial Fuels, Mineral Wool, Insulation Material, Refractory/Ceramic Fibres, Glass Yarn -
may be harmful if inhaled,
may be irritating to skin, eyes, nose and throat.
When handling
avoid inhaling and contact with skin or eyes. Use disposable gloves, facemasks and eye protection.
After handling wash hands and other exposed parts. If a vacuum is used for cleaning the Logs or cleaning after servicing
/ installation it is recommended that it be of the type fitted with a HEPA filter.
Disposal of refractory/ceramic materials
. To keep dust to a minimum these materials should be securely wrapped in
polythene and be clearly labelled ‘RCF waste’. These materials are not classified as ‘hazardous waste and should be
disposed of at a site licensed for the disposal of industrial waste.
Introduction
•
The Edge / Edge 3s BF has been designed and tested for use in GB (Great Britain) and IE (Ireland).
•
The Edge / Edge 3s BF incorporates a single gas valve which selects ignition pilot, with variable setting
between low and high setting and is operated via remote control hand device .
This system is powered by mains
electricity via pre-wired transformer plus supply cord. Alternative power supply is available for users during mains
interruptions.
•
The Edge / Edge 3s BF is an inset room sealed decorative fuel-effect gas appliance.
•
The Edge / Edge 3s BF is available in natural gas or LPG
.
•
The Edge / Edge 3s BF
must not
be installed into a natural draught flue or chimney.
•
The Edge / Edge 3s BF should only be installed and serviced by a competent person i.e. GAS SAFE registered,
in accordance with the GAS SAFETY (INSTALLATION AND USE) REGULATIONS.
•
The Edge / Edge 3s BF does not require a chimney, but
must be
installed so it can flue to an outside wall.
•
It is important that the flue terminal is regularly checked and kept clear at all times.
•
If the terminal is accessible to people (i.e. less than 2m above a walkway, balcony etc.) a terminal guard must
be fitted to prevent access to the flue outlet, which becomes hot when the fire is in use.
•
As the Edge / Edge 3s BF is a room sealed appliance (i.e. air for the combustion process is taken from outside
the room) no purpose built ventilation is required.
•
The Edge / Edge 3s BF is designed and tested to meet the requirements of the European Standard EN 613.
Summary of Contents for Edge 3s BF
Page 15: ...www charltonandjenrick co uk 15 LT8019 Appliance Dimensions EDGE BF EDGE 3s BF ...
Page 21: ...www charltonandjenrick co uk 21 LT8019 ...
Page 22: ...22 LT8019 ...
Page 32: ...32 LT8019 SECTION FOURTEEN Wiring Diagram Maintenance Instructions ...
Page 34: ...34 LT8019 Register your appliance online today to active your warranty ...
Page 37: ...www charltonandjenrick co uk 37 LT8019 ...
Page 38: ...38 LT8019 ...